Key result
Digital ECG core lab analysis shows large inconsistencies versus visual measurements, matching only ~39% of maximal ST-segments.
Why the study?
The utility and reliability of a central operator-assisted digital ECG core laboratory for interpreting epicardial ECG ST-segment shifts from multiple clinical sites was uncertain.
Does an operator-assisted digital ECG core laboratory provide more consistent ST-segment shift measurements compared to visual assessment by clinical investigators in patients undergoing angioplasty?
Observational
Yes
Does an operator-assisted digital ECG core laboratory provide more consistent ST-segment shift measurements compared to visual assessment by clinical investigators in patients undergoing angioplasty?
Digital core laboratory assessment of epicardial ECGs reveals significant inconsistencies in manual visual measurements by site investigators, supporting the use of core labs in clinical trials.
Answers are grounded in this paper and cite their sources.
May warrant caution using operator-assisted digital ECG core labs clinically; leaves open standardization of ECG methods for trials.
BACKGROUND: The epicardial electrocardiogram (ECG) is a sensitive marker for cardiac ischemia and has been used as a measure of ischemia in clinical trials. We sought to examine the utility of a central ECG laboratory for determining ischemic-type ST-segment shifts from epicardial ECG recordings obtained from multiple clinical sites. HYPOTHESIS: We speculated that an operator-assisted digital ECG core laboratory is feasible, reliable, and efficient, with the ability for rapid and accurate interpretation of the epicardial ECG. METHODS: The epicardial ECG was recorded via an angioplasty guidewire placed in a coronary artery of a patient undergoing angioplasty. Site investigators visually determined the time-to-onset of 0.1 and 0.3 mm ST-segment elevation, and the maximal ST-segment elevation during balloon inflation, and then compared the measurements with those made at an operator-assisted digital ECG core laboratory. RESULTS: Agreement between the two methods occurred in 78% of the time-to-onset measurements, but in only 39% of the maximal ST-segment measurements. Overall, the visual measurements of the clinical investigators of time-to-onset differed from the digital core laboratory by 11.8 +/- 11.6 s for 0.1 mV, and 15.8 +/- 20.6 s for 0.3 mV. Recorded maximal ST-segment shifts differed by a mean of 0.47 +/- 0.69 mV. CONCLUSION: The magnitude of inconsistency between the ECG core laboratory results using an operator-assisted digital method and the interpretations of clinical investigators using manual caliper-type analysis was surprisingly large. These results support the need for an ECG core laboratory in clinical trials where ECG ST-segment shifts are used as a response variable.
No takes yet. Share an insight, caveat, or question.
Hurst et al. (1999) conducted an observational in Patients undergoing angioplasty. Operator-assisted digital ECG core laboratory analysis vs. Visual measurements by clinical investigators was evaluated on Agreement between digital core laboratory and visual measurements for time-to-onset and maximal ST-segment elevation. Operator-assisted digital ECG core laboratory analysis showed large inconsistencies compared to visual measurements, with agreement in only 78% of time-to-onset and 39% of maximal ST-segment measurements.