Key result
3-D printable FBG sensors achieve high resolution under 2.5 mN for catheter surgical robots.
Why the study?
Proximal force signals are critical for enhancing the safety of catheter surgical robots, but high-resolution, sensitive, and reliable sensors are needed for effective force measurement and control.
The newly designed FBG-based proximal force sensors offer high resolution and sensitivity, showing potential to enhance the safety and control of catheter surgical robots.
May enhance robotic catheter safety; leaves open clinical translation pending in vivo trials.
Proximal force signals are widely used benefiting from the advantage of easy collection and are critical for enhancing the safety of the catheter surgical robot. This article presented two kinds of 3-D printable fiber Bragg grating (FBG)-based sensors for clamping force and axial force sensing. The clamping force sensor can realize the clamping–sensing function integration based on a 45° inclined rod and an arc hinge, while the axial force sensor adopts two symmetrical lamina emergent torsional (LET) joints to enhance the sensitivity and hysteresis characteristic. A data and theoretical model-driven method has been proposed to derive sensitivity models of sensors, and the relative errors compared with the experimental sensitivities are all within 10%. The calibration experiment results demonstrate that the designed sensor has obvious benefits in resolution (< 2.5 mN) and sensitivity (480 pm/N) compared with other similar sensors. In addition, dynamic and durability experiments have been implemented to validate the reliability of the designed sensors. To achieve direct measurement of proximal force and reduce the influence of parasitic movement, the integration mode of two sensors is also carefully considered. A wireless technology-based primary–secondary control system and a fuzzy proportional–integral–derivative (PID) control strategy with overshoot compensation have been constructed, leading to the achievement of automatic adjustment of catheter movement and clamping force. Furthermore, several in vitro experiments have been implemented to verify the vascular protection, primary–secondary hand switching, and grading force control functions of the system. Such merits indicate that the designed proximal force sensors have huge potential in the field of catheter surgical robots.
No takes yet. Share an insight, caveat, or question.
Li et al. (2023) studied this question. 3-D printable fiber Bragg grating (FBG)-based sensors vs. other similar sensors was evaluated on resolution and sensitivity. The designed 3-D printable FBG-based sensors demonstrated high resolution (<2.5 mN) and sensitivity (480 pm/N) for catheter surgical robots in calibration and in vitro experiments.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: