Key result
Higher FIB-4 index predicts ~10% greater odds of a non-dipper blood pressure pattern in newly diagnosed hypertension.
Why the study?
The relationship between the fibrosis-4 index and epicardial fat tissue in newly diagnosed hypertensive patients and its ability to predict non-dipper blood pressure patterns was unclear.
Does the FIB-4 index predict a non-dipper blood pressure pattern in patients with newly diagnosed hypertension?
Case-Control (n=210)
Does the FIB-4 index predict a non-dipper blood pressure pattern in patients with newly diagnosed hypertension?
Odds Ratio: 1.099 (95% CI 1.621–5.556)
p-value: p=<0.001
The FIB-4 index is positively correlated with epicardial fat tissue and serves as an independent predictor of the non-dipper blood pressure pattern in newly diagnosed hypertensive patients.
Hypothesis-generating for FIB-4 in non-dipper hypertension; prospective validation needed before clinical adoption.
Introduction: Epicardial fat tissue (EFT) is a significant risk factor for cardiovascular diseases. This study aimed to investigate whether there is a relationship between the fibrosis-4 index (FIB-4 index) and EFT in newly-diagnosed hypertensive patients and explore the usability of the FIB-4 index in predicting non-dipper blood pressure (BP) pattern. Materials and methods: Our case–control study consisted of 210 patients in 3 groups according to BP values, namely normotensive, dipper, and non-dipper groups. Transthoracic echocardiography and 24-h ambulatory BP monitoring were performed in all patients. Results: The median FIB-4 index was higher in the non-dipper group [1.56 (1.10-2)] than in the dipper [1 (0.71-1.32)] and normotensive groups [0.96 (0.69-1.32)] (p < 0.001, for both). A positive correlation was observed between EFT and the FIB-4 index (r=0.389, p<0.001). In multivariate logistic regression analysis, EFT (odds ratio (OR): 0.506, 95% confidence interval (CI): 1.288-2.135; p<0.001) and FIB-4 index (OR: 1.099, 95% CI: 1.621–5.556; p<0.001) were found to be independent predictors of non-dipper BP. In the receiver operating characteristic curve analysis, the FIB-4 index had 68% sensitivity and 72% specificity at a value >1.25 (area under the curve: 0.751, 95%CI: 0.679-0.823, p<0.001). Conclusions: In newly-diagnosed hypertensive people, the FIB-4 index is related to non-dipper BP patterns. FIB-4 index appears to be a helpful tool in assessing risk associated with cardiovascular disease.
No takes yet. Share an insight, caveat, or question.
Küçük et al. (2022) conducted a case-control in Newly diagnosed hypertension (n=210). Fibrosis-4 index (FIB-4 index) vs. Dipper and normotensive blood pressure patterns was evaluated on Non-dipper blood pressure pattern (OR 1.099, 95% CI 1.621-5.556, p=<0.001). The FIB-4 index was an independent predictor of a non-dipper blood pressure pattern in newly-diagnosed hypertensive patients (OR 1.099; 95% CI 1.621-5.556; p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: