Answers are grounded in this paper and cite their sources.
This work investigates the transport and accumulation patterns of non-combusting ember particles carried via wind over sample buildings using PyroSim simulation software. The simulations use ember particles with a radius of 2.5 mm and a density of 60 kg/m3 to ensure realistic transport and deposition, consistent with values reported for firebrands such as those from Oriented Strand Boards. A horizontal wind speed of 5 m/s and vertical speed of 3 m/s are chosen to reflect typical wildfire conditions, notably Santa Ana winds, as indicated in the literature, while facilitating loft and settling. These parameters are selected to balance physical realism with computational efficiency and to match ember fluxes observed in field experiments. The results indicate that roofs with a ridge line perpendicular to the wind direction are more likely to accumulate embers. Regardless of building geometry, a significant portion of embers consistently accumulates along the windward walls of structures, representing a critical ignition risk. Additional trials show that ember deposition within the critical ember-resistant zone can be reduced when balconies or trees are placed in front of or along the sides of houses, with decreases reaching up to 25% in some configurations. These findings highlight the influence of both roof geometry and nearby obstacles on ember accumulation, offering insights for mitigation strategies in Wildland – Urban Interface design.
No takes yet. Share an insight, caveat, or question.
Gellerman et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: