The application of an electric field to an ion‐conducting glass at high temperatures will cause depletion of mobile ions beneath a blocking anode. The present study extends the investigation of ion depletion to several types of ion‐conducting glass and presents new data for the physical and chemical properties of depleted surfaces. Ion‐scattering spectrometry and electron microprobe analysis show that all positive monovalent and divalent ions are removed from the vicinity of the anode. The less mobile ion species are observed to pile up beneath the depleted region. Experimental data indicate that the removal of ions from the vicinity of the anode creates a microporous region that densifies at a rate determined by glass composition, temperature, and voltage. Ion‐depleted surfaces display a lower refractive index and an increased electrical resistivity compared to untreated glass. Ion depletion also imparts an enhanced chemical durability to glass surfaces and increases the breaking strength of some glasses.
No takes yet. Share an insight, caveat, or question.
Carlson et al. (1974) studied this question.