Key result
Transesophageal EPS shows ~89% negative predictive value for pediatric tachycardia nonrecurrence.
Why the study?
The diagnostic capability, negative predictive value of noninducibility of tachycardia, and safety of TEEPS in the Indian pediatric population were not well established.
Does transesophageal electrophysiological study (TEEPS) accurately predict the recurrence of tachycardia and is it safe in pediatric patients?
Observational (n=18)
No
Does transesophageal electrophysiological study (TEEPS) accurately predict the recurrence of tachycardia and is it safe in pediatric patients?
TEEPS is a safe procedure in pediatric patients, and noninducibility of tachycardia has a high negative predictive value for midterm clinical recurrence.
Supports TEEPS noninducibility for pediatric SVT risk stratification; leaves open need for prospective validation before wider adoption.
Background: Transesophageal electrophysiological study (TEEPS) is a minimally invasive procedure that helps in evaluating the risk of recurrence of supraventricular tachycardia based on the inducibility of the tachycardia. The purpose of this study was to evaluate the diagnostic capability, negative predictive value of noninducibility of tachycardia and safety of TEEPS among the Indian pediatric population. Methods: It is a retrospective single-center observational study of all patients who underwent TEEPS from January 01, 2014, to December 31, 2020. Results: Twenty-two TEEPS procedures were done in eighteen children with three children undergoing more than one procedure. The median duration of follow-up was 42.97 months (8.52-82.12 months). Out of the 22 procedures, four were conducted for acute tachycardia termination, two for tachycardia suppression assessment, and sixteen to assess tachycardia inducibility off medications. Tachycardia was noninducible in nine children and inducible in six children. Two children had clinical recurrence of tachycardia on follow-up. Out of these two children, one had noninducibility of tachycardia on TEEPS. The negative predictive value of TEEPS was 88.89% in this study. None of the children had any postprocedure complication. Conclusions: TEEPS is a safe procedure. It is used to assess the efficacy of medication in the suppression of arrhythmia. The noninducibility of tachycardia has a high negative predictive value and is a good indicator of nonrecurrence of clinical tachycardia on midterm follow-up.
No takes yet. Share an insight, caveat, or question.
Manickavasagam et al. (2022) conducted an observational in pediatric tachyarrhythmias (n=18). Transesophageal electrophysiological study (TEEPS) was evaluated on negative predictive value of noninducibility of tachycardia. Transesophageal electrophysiological study demonstrated an 88.89% negative predictive value for the nonrecurrence of clinical tachycardia in pediatric patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: