Key result
ECG-synchronized CTA measures ascending aortic distensibility and compliance, which correlate with age and SBP.
Why the study?
Modernization of CTA protocols with advanced data processing is needed to improve diagnosis and assessment of ascending aortic aneurysms by determining aortic distensibility and compliance.
Does ECG-synchronized CTA with advanced data processing allow evaluation of aortic distensibility and compliance in patients with ascending aortic aneurysm or dilatation?
Observational (n=24)
Does ECG-synchronized CTA with advanced data processing allow evaluation of aortic distensibility and compliance in patients with ascending aortic aneurysm or dilatation?
ECG-synchronized CTA with advanced data processing can evaluate ascending aortic distensibility and compliance, providing additional information on elastic properties that may guide management strategy.
ECG-synchronized CTA may quantify aortic stiffness in aneurysm patients; hypothesis-generating for risk stratification before prospective validation.
Aim. To modernize the computed tomography angiography (CTA) protocol with advanced data processing for the diagnosis of ascending aortic (AA) aneurysms, determining the aortic distensibility and compliance. Material and methods. We examined 24 patients (14 men) aged 43 to 72 years old with aneurysm or dilatation of ascending aorta (AA). CTA was performed on Siemens Somatom Definition AS and Philips Ingenuity Elite 128-slice scanners with electrocardiographic (ECG) synchronization after a bolus injection of contrast agents (100-120 ml). End-systolic and end-diastolic frames, maximum aortic diameter and cross-sectional area were determined; aortic distensibility and compliance were calculated. Results. According to AA diameter in end-diastolic frame, patients were divided into 3 groups. Group 1 — 6 patients, d< 45 mm (39 [39; 40] mm), group 2 — 7 patients, d =45-50 mm (48 [46; 49] mm) and group 3 — 11 patients, d >50 mm (51 [51; 54] mm). A correlation between aortic distensibility and compliance and such parameters as age, systolic blood pressure, systolic and was found. Correlation between the aortic compliance and diastolic diameter can be used for predicting of diameter increase rate. Conclusion. The designed CTA protocol with advanced data processing allows evaluating the AA distensibility and compliance by the diameter and cross-sectional area in patients with AA dilatation. These criteria provide additional information about the aortic elastic properties and can be used for determining the management strategy.
No takes yet. Share an insight, caveat, or question.
Skripnik et al. (2019) conducted an observational in Aneurysm or dilatation of ascending aorta (n=24). ECG-synchronized computed tomography angiography was evaluated on Aortic distensibility and compliance. ECG-synchronized computed tomography angiography allowed evaluation of ascending aortic distensibility and compliance, which correlated with age and systolic blood pressure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: