Background In this study we evaluated the imaging capabilities of a novel Multi-pinhole collimator (MPH-Cardiac) specially designed for nuclear cardiology imaging on a Triple-NaI-detector based SPECT/CT system. Methods 99m Tc point source measurements covering the field of view (FOV) were used to determine tomographic sensitivity (TS pointsource ) and spatial resolution. Organ-size tomographic sensitivity (TS organ ) was measured with a left ventricle (LV) phantom filled with typical myocardial activity of a patient scan. Reconstructed image uniformity was measured with a 140 mm diameter uniform cylinder phantom. Using the LV phantom once filled with 99m Tc and after with 123 I, Contrast-to-noise ratio (CNR) was measured on the reconstructed images by ROI analysis on the myocardium activity and on the LV cavity. Furthermore, a polar map analysis was performed determining Spill-Over-Ratio in water (SOR water ) and image noise. The results were compared with that of a dual-head parallel-hole low energy high resolution (LEHR) collimator system. A patient with suspected coronary artery disease (CAD) was scanned on the LEHR system using local protocol of 16 min total acquisition time, followed by a 4-min MPH-Cardiac scan. Results Peak TS pointsource was found to be 1013 cps/MBq in the axial center of the FOV while it was decreasing toward the radial edges. TS organ in the CFOV was found to be 134 cps/MBq and 700 cps/MBq for the LEHR and MPH-Cardiac, respectively. Average spatial resolution throughout the FOV was 4.38 mm FWHM for the MPH-Cardiac collimator. Reconstructed image uniformity values were found to be 0.292% versus 0.214% for the LEHR and MPH-Cardiac measurements, respectively. CNR was found to be higher in case of MPH-Cardiac than for LEHR in case of 99m Tc (15.5 vs. 11.7) as well as for 123 I (13.5 vs. 8.3). SOR water values were found to be 28.83% and 21.1% for the 99m Tc measurements, and 31.44% and 24.33% for the 123 I measurements for LEHR and MPH-Cardiac, respectively. Pixel noise of the 99m Tc polar maps resulted in values of 0.38% and 0.24% and of the 123 I polar maps 0.62% and 0.21% for LEHR and MPH-Cardiac, respectively. Visually interpreting the patient scan images, MPH-Cardiac resulted in better image contrast compared to the LEHR technique with four times shorter scan duration. Conclusions The significant image quality improvement achieved with dedicated MPH-Cardiac collimator on triple head SPECT/CT system paves the way for short acquisition and low-dose cardiovascular SPECT applications.
No takes yet. Share an insight, caveat, or question.
Krizsan et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: