Key result
18F-LMI1195 shows homogeneous transmural distribution in healthy rabbits versus lower subepicardial uptake with 201Tl.
Why the study?
A detailed regional ventricular distribution pattern of the novel cardiac nerve PET radiotracer 18F-LMI1195 in healthy rabbit hearts was not established.
The novel sympathetic nerve PET radiotracer 18F-LMI1195 demonstrates a homogeneous transmural distribution in healthy rabbit hearts, which differs slightly from the perfusion marker 201Tl.
Answers are grounded in this paper and cite their sources.
May guide sympathetic PET tracer development; leaves open translation to diseased hearts or humans.
We aimed to determine a detailed regional ventricular distribution pattern of the novel cardiac nerve PET radiotracer 18F-LMI1195 in healthy rabbits. Ex-vivo high resolution autoradiographic imaging was conducted to identify accurate ventricular distribution of 18F-LMI1195. In healthy rabbits, 18F-LMI1195 was administered followed by the reference perfusion marker 201Tl for a dual-radiotracer analysis. After 20 min of 18F-LMI1195 distribution time, the rabbits were euthanized, the hearts were extracted, frozen, and cut into 20-μm short axis slices. Subsequently, the short axis sections were exposed to a phosphor imaging plate to determine 18F-LMI1195 distribution (exposure for 3 h). After complete 18F decay, sections were re-exposed to determine 201Tl distribution (exposure for 7 days). For quantitative analysis, segmental regions of Interest (ROIs) were divided into four left ventricular (LV) and a right ventricular (RV) segment on mid-ventricular short axis sections. Subendocardial, mid-portion, and subepicardial ROIs were placed on the LV lateral wall. 18F-LMI1195 distribution was almost homogeneous throughout the LV wall without any significant differences in all four LV ROIs (anterior, posterior, septal and lateral wall, 99 ± 2, 94 ± 5, 94 ± 4 and 97 ± 3%LV, respectively, n.s.). Subepicardial 201Tl uptake was significantly lower compared to the subendocardial portion (subendocardial, mid-portion, and subepicardial activity: 90 ± 3, 96 ± 2 and *80 ± 5%LV, respectively, *p < 0.01 vs. mid-portion). This was in contradistinction to the transmural wall profile of 18F-LMI1195 (90 ± 4, 96 ± 5 and 84 ± 4%LV, n.s.). A slight but significant discrepant transmural radiotracer distribution pattern of 201Tl in comparison to 18F-LMI1195 may be a reflection of physiological sympathetic innervation and perfusion in rabbit hearts.
No takes yet. Share an insight, caveat, or question.
Werner et al. (2019) studied Healthy (n=4). 18F-LMI1195 vs. 201Tl was evaluated on Transmural radiotracer distribution pattern (subendocardial, mid-portion, and subepicardial activity). 18F-LMI1195 demonstrated a homogeneous transmural distribution pattern across the left ventricular wall in healthy rabbits, whereas the perfusion marker 201Tl showed significantly lower subepicardial uptake.
Synapse has enriched 10 related papers. Consider them for comparative context: