Key result
Thoracoscopic epicardial electrode implantation using automated titanium fasteners appears feasible and maintains 60% EF.
Why the study?
Published reports on thoracoscopic pacemaker implantation mostly describe monopolar screw-in leads, with limited data on bipolar suture-on epicardial electrodes using automated fasteners.
Case Report (n=1)
Thoracoscopic implantation of epicardial bipolar suture-on leads using automated titanium fasteners is feasible and safe for patients with unfavorable venous access requiring left ventricular lead placement.
BACKGROUND: Pacemaker implantation techniques using thoracoscopy have been described since about 25 years. However, the published reports concerning types of electrodes refer mostly to monopolar screw-in leads. We report our experience of thoracoscopic implantation of a bipolar suture-on epicardial electrode with monofilamentous sutures tightened by automated fasteners to avoid hand-tied knots. CASE PRESENTATION: A 69-year-old Caucasian female patient with a cardiac resynchronization therapy - defibrillator (CRT-D) due to dilated cardiomyopathy required the implantation of a supplementary left ventricluar resynchronization electrode. Because of unfavorable venous access, we chose a thoracoscopic approach. A bipolar suture-on epicardial electrode, was implanted by means of polypropylene monofilament 2-0 threads and automated titanium fasteners (Cor-Knot®). The intervention was uneventful. The correct function of the device was confirmed postoperatively and the patient was dismissed within 3 days from hospital. Six months after implantation the cardiologic control asserted regular device function and restitution of normal ejection fraction (EF 60%). CONCLUSION: This case demonstrates the feasibility, safety and effectiveness of automated fasteners in the setting of thoracoscopic implantation of epicardial bipolar suture-on leads.
No takes yet. Share an insight, caveat, or question.
Schaeffer et al. (2019) conducted a case report in Dilated cardiomyopathy requiring supplementary left ventricular resynchronization electrode (n=1). Thoracoscopic implantation of a bipolar suture-on epicardial electrode using automated titanium fasteners (Cor-Knot®) was evaluated on Feasibility, safety, and effectiveness (device function and ejection fraction). Thoracoscopic implantation of a bipolar suture-on epicardial electrode using automated titanium fasteners was feasible and safe, resulting in regular device function and normal ejection fraction (60%) at 6 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: