Key result
Subtotal resection of infant cardiac fibroma eliminates arrhythmogenic substrate, allowing ICD removal after 5 years.
Why the study?
Complete elimination of arrhythmogenic substrates after subtotal resection of congenital cardiac fibroma in infants with medication-resistant ventricular arrhythmias has been unclear.
Case Report (n=1)
Subtotal resection of congenital cardiac fibroma can lead to complete elimination of arrhythmogenic substrates, allowing for eventual ICD removal.
Answers are grounded in this paper and cite their sources.
Subtotal resection may enable later ICD removal in infantile cardiac fibroma; hypothesis-generating and requires prospective confirmation before broader adoption.
Subtotal tumour resection is used to treat infants with congenital cardiac fibroma and medication-resistant ventricular arrhythmias; however, complete elimination of arrhythmogenic substrates has been unclear. A 4-month-old male infant with congenital cardiac fibroma and ventricular fibrillation underwent subtotal tumour resection and implantable cardioverter-defibrillator implantation. Five years later, angiography revealed impending compression of the left coronary artery. Elimination of the arrhythmogenic substrate was confirmed and the device was removed successfully.
No takes yet. Share an insight, caveat, or question.
Nabeshima et al. (2019) conducted a case report in Congenital cardiac fibroma and ventricular fibrillation (n=1). Subtotal tumour resection and implantable cardioverter-defibrillator implantation was evaluated on Elimination of arrhythmogenic substrate. Subtotal tumour resection of a congenital cardiac fibroma in a 4-month-old infant successfully eliminated the arrhythmogenic substrate, allowing for ICD removal 5 years later.