Key result
Subtotal tumour resection and ICD implantation eliminates arrhythmogenic substrate at 5 years in infant cardiac fibroma.
Why the study?
Complete elimination of arrhythmogenic substrates after subtotal resection of congenital cardiac fibroma in infants with medication-resistant ventricular arrhythmias has been unclear.
Case Report (n=1)
Subtotal resection of congenital cardiac fibroma may lead to long-term elimination of arrhythmogenic substrates, allowing for subsequent ICD removal.
Answers are grounded in this paper and cite their sources.
May support ICD explantation after subtotal resection in infant cardiac fibroma; hypothesis-generating and requires prospective validation.
Subtotal tumour resection is used to treat infants with congenital cardiac fibroma and medication-resistant ventricular arrhythmias; however, complete elimination of arrhythmogenic substrates has been unclear. A 4-month-old male infant with congenital cardiac fibroma and ventricular fibrillation underwent subtotal tumour resection and implantable cardioverter-defibrillator implantation. Five years later, angiography revealed impending compression of the left coronary artery. Elimination of the arrhythmogenic substrate was confirmed and the device was removed successfully.
No takes yet. Share an insight, caveat, or question.
Nabeshima et al. (2018) conducted a case report in Congenital cardiac fibroma and ventricular fibrillation (n=1). Subtotal tumour resection and implantable cardioverter-defibrillator implantation was evaluated on Elimination of arrhythmogenic substrate. Subtotal tumour resection and ICD implantation in a 4-month-old infant with congenital cardiac fibroma resulted in the confirmed elimination of the arrhythmogenic substrate at 5 years.
Synapse has enriched 10 related papers. Consider them for comparative context: