Key result
Pediatric deep anesthesia airway removal adverse events are ~97% respiratory and cause no permanent harm.
Why the study?
Previous studies on removal of endotracheal tubes and supraglottic devices under deep anesthesia in children were underpowered to identify rare complications.
What are the complications associated with the removal of airway devices under deep anesthesia in children?
Observational (n=66)
Yes
What are the complications associated with the removal of airway devices under deep anesthesia in children?
Removal of airway devices under deep anesthesia in children is associated with serious, often preventable respiratory adverse events, including cardiac arrest, though long-term harm is rare.
Answers are grounded in this paper and cite their sources.
Serious respiratory events including arrest can occur with deep extubation in children but resolve without harm; hypothesis-generating and should not yet change practice.
Background: Previous studies examining removal of endotracheal tubes and supraglottic devices under deep anesthesia were underpowered to identify rare complications. This study sought to report all adverse events associated with this practice found in a large national database of pediatric anesthesia adverse events.Methods: An extract of an adverse events database created by the Wake Up Safe database, a multi-institutional pediatric anesthesia quality improvement initiative, was performed for this study. It was screened to identify anesthetics with variables indicating removal of airway devices under deep anesthesia. Three anesthesiologists screened the data to identify events where this practice possibly contributed to the event. Event data was extracted and collated. Results: 102 events met screening criteria and 66 met inclusion criteria. Two cardiac etiology events were identified, one of which resulted in the patient’s demise. The remaining 97% of events were respiratory in nature (64 events), including airway obstruction, laryngospasm, bronchospasm and aspiration. Some respiratory events consisted of multiple distinct events in series. Nineteen respiratory events resulted in cardiac arrest (29.7%) of which 15 (78.9%) were deemed preventable by local anesthesiologists performing independent review. Respiratory events resulted in intensive care unit admission (37.5%), prolonged intubation and temporary neurologic injury but no permanent harm. Provider and patient factors were root causes in most events. Upon investigation, areas for improvement identified included improving patient selection, ensuring monitoring, availability of intravenous access, and access to emergency drugs and equipment until emergence.Conclusions: Serious adverse events have been associated with this practice, but no respiratory events were associated with long-term harm.
No takes yet. Share an insight, caveat, or question.
Vitale et al. (2021) conducted an observational in Adverse events following removal of airway devices under deep anesthesia (n=66). Removal of airway devices under deep anesthesia was evaluated on Adverse events associated with removal of airway devices under deep anesthesia. Among 66 adverse events associated with removal of airway devices under deep anesthesia in children, 97% were respiratory in nature, with 19 progressing to cardiac arrest, but none caused permanent harm.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: