Key result
Stable-phase ECG J-waves linked to ~289% higher VF risk in ICD patients.
Why the study?
The clinical implication of the J-wave as a predictor of life-threatening ventricular arrhythmia in ICD patients is still unclear.
Does the presence of a J-wave predict ventricular fibrillation or ventricular tachycardia events in patients with an implantable cardioverter defibrillator?
Cohort (n=170)
No
Does the presence of a J-wave predict ventricular fibrillation or ventricular tachycardia events in patients with an implantable cardioverter defibrillator?
Hazard Ratio: 3.886 (95% CI 1.313–10.568)
p-value: p=0.012
The presence of a J-wave on a stable phase ECG is an independent predictor of ventricular fibrillation events in patients with an ICD.
J-wave on stable ECG associated with VF in ICD patients; hypothesis-generating and should not yet change practice.
The J-wave has been reported to be associated with life-threatening ventricular arrhythmia. However, the clinical implication of the J-wave is still unclear in patients with an implantable cardioverter defibrillator (ICD).The study population consisted of 170 ICD patients (age, 56 ± 16 years, 79.4% male) treated at Kitasato University Hospital between 2003 and 2014. Ventricular fibrillation (VF) and ventricular tachycardia (VT) events were documented via ICD interrogation, and the patients were divided into 3 groups: 1) VF event group, 2) VT event group, and 3) No-event group. To predict VT or VF events, univariate and multivariate analysis of clinical data including ECG findings were performed. A J-wave was defined as the presence of notching or slurring of the QRS complex (≥ 0.1 mV) in inferior/lateral leads. Among the 170 patients examined, 23 experienced VF and 38 experienced VT during 54 ± 39 months follow-up. In the multivariate Cox proportional hazards model, the J-wave was identified as an independent predictor for a VF event (HR: 3.886, 95% CI: 1.313-10.568, P = 0.012). In contrast, BNP (HR: 1.002, 95% CI: 1.000-1.003, P = 0.043) and left ventricular diastolic diameter (HR: 1.039, 95% CI: 1.002-1.081, P = 0.049) were independent predictors for a VT event.The results suggest J-waves in the stable phase in an ECG may be a useful predictor for a VF event in ICD patients.
No takes yet. Share an insight, caveat, or question.
Ishizue et al. (2017) conducted a cohort in Implantable cardioverter defibrillator (ICD) patients (n=170). J-wave in the stable phase on ECG vs. Absence of J-wave was evaluated on Ventricular fibrillation (VF) event (HR 3.886, 95% CI 1.313-10.568, p=0.012). The presence of a J-wave in the stable phase on an ECG independently predicted a ventricular fibrillation event in patients with an implantable cardioverter defibrillator (HR 3.886).