Why the study?
Misalignment and motion artifacts in CCTA images affect diagnostic CT performance in patients with elevated heart rates or arrhythmia, necessitating evaluation of advanced CT technology for left atrial assessment.
Can 256-slice CCTA effectively measure and detect differences in left atrial volume between patients with high heart rate and those with atrial fibrillation?
Observational (n=223)
Can 256-slice CCTA effectively measure and detect differences in left atrial volume between patients with high heart rate and those with atrial fibrillation?
Answers are grounded in this paper and cite their sources.
Current-generation 256-slice CCTA can effectively measure left atrial volume and index in patients with high heart rates or atrial fibrillation, demonstrating significantly larger volumes in AFib patients.
We intended to assess the ability of current-generation 256-slice coronary CT angiography (CCTA) to measure left atrial volume (LAV), comparing patients with a high heart rate (HiHR) of at least 70 bpm and patients with heart rate variability such as atrial fibrillation (AFib). Methods: Using the prospective Converge Registry of patients undergoing 256-detector CCTA on a Revolution scanner, we enrolled 121 HiHR patients (74 men; mean age, 62.7 ± 12.5 y) and 102 AFib patients (72 men; mean age, 60.5 ± 11.0 y) after obtaining informed consent. Quantitative data analysis of LAV was performed using automated methods, and end-systolic phases were chosen for measurements from CCTA. A Student t test, Wilcoxon rank-sum test, or χ2 test assessed baseline parameters. Univariate and multivariate linear regression analysis was used to assess LAV and LAV index (LAVI) while adjusting potentially confounding variables. Results: Mean LAV was significantly higher in AFib subjects (148.6 ± 57.2 mL) than in HiHR subjects (102.1 ± 36.5 mL) (P < 0.0001). Similarly, mean LAVI was significantly higher in AFib subjects (72.4 ± 28.1 mL/m2) than in HiHR subjects (51.5 ± 19.0 mL/m2) (P < 0.0001). After adjusting for age, body mass index, sex, diabetes, hypertension, hyperlipidemia, and smoking, subjects with AFib had, on average, LAV measures higher by 41.2 ± 6.7 mL and LAVI values higher by 23.1 ± 3.4 mL/m2 (P < 0.0001). Conclusion: Misalignment and motion artifacts in CCTA images affect diagnostic CT performance, especially in patients with elevated heart rates or profound arrhythmia. However, the new-generation Revolution CCTA provides detailed information on left-atrium-complex morphology and function, in addition to coronary anatomy, in HiHR and AFib patients without additional radiation, scanning, or contrast requirements.
No takes yet. Share an insight, caveat, or question.
Cherukuri et al. (2020) conducted an observational in High heart rate or atrial fibrillation (n=223). Atrial fibrillation vs. High heart rate (≥70 bpm) was evaluated on Left atrial volume (LAV) (MD 41.2, p=<0.0001).
Synapse has enriched 10 related papers. Consider them for comparative context: