Key result
Primary prevention ICD recipients report similar quality of life to secondary prevention recipients.
Why the study?
The quality-of-life effects of implantable cardioverter-defibrillators among primary prevention patients are not well understood.
Does health-related quality of life differ between primary and secondary prevention ICD recipients?
Cross-Sectional (n=120)
No
Does health-related quality of life differ between primary and secondary prevention ICD recipients?
Quality of life and device acceptance are comparable between primary and secondary prevention ICD recipients, though both groups share specific concerns regarding lifting, sexual activity, and driving.
Answers are grounded in this paper and cite their sources.
QOL comparable across primary and secondary prevention ICD recipients; observational data leave open effects on distress or adaptation in broader cohorts.
BACKGROUND: Although patients receiving implantable cardioverter-defibrillators (ICDs) for primary prevention of sudden cardiac death are the fastest growing segment of the ICD recipient population, the quality-of-life (QOL) effects of the ICD among primary prevention patients are not well understood. The purpose of this study was to measure and compare the health-related QOL among primary and secondary prevention ICD recipients, and to determine predictive factors for high or low QOL in each group. METHODS: Forty-five primary prevention and 75 secondary prevention ICD recipients receiving routine care in electrophysiology clinics within the University of Pennsylvania Health System were assessed using several well-validated general and ICD-specific QOL instruments. RESULTS: Between primary and secondary prevention patients, there were no significant differences in EuroQol 5D (medians: 0.84 vs 0.84, P = 0.71), Health Utilities Index (medians: 0.88 vs 0.85, P = 0.95), Short Form-12 aggregate physical summary (means: 45 vs 46, P = 0.64), and Short Form-12 aggregate mental summary (means: 46 vs 47, P = 0.93) scores. Both primary and secondary prevention patients viewed their devices favorably according to the Florida Patient Acceptance Survey scale, with no significant differences between group means (80 vs 83, P = 0.71). However, substantial fractions of both primary and secondary prevention recipients had particular concerns about lifting (40%), sexual activity (19%), and driving (14%). CONCLUSIONS: QOL does not significantly differ between primary prevention and secondary prevention ICD recipients. Device recipients had comparable QOL to published, nationwide QOL estimates among non-ICD patients of similar age. The ICD was highly acceptable to most primary and secondary prevention patients.
No takes yet. Share an insight, caveat, or question.
Groeneveld et al. (2007) conducted a cross-sectional in Implantable cardioverter-defibrillator (ICD) recipients (n=120). Primary prevention ICD vs. Secondary prevention ICD was evaluated on EuroQol 5D score (p=0.71). Primary prevention ICD recipients had similar quality of life compared to secondary prevention recipients, with median EuroQol 5D scores of 0.84 in both groups.
Synapse has enriched 10 related papers. Consider them for comparative context: