A direct determination of the Poisson’s ratio in 150 nm polycrystalline tungsten thin films deposited by ion-beam sputtering on Duralumin substrates has been performed by combining x-ray diffraction measurements with in situ traction on the sample. X-ray diffraction experiments using the sin2 ψ method have been done at LURE, the French synchrotron facility (Orsay, France) on a four-circle diffractometer. The method described in this letter allows us to extract in a simple way and with a good precision the Poisson’s ratio of thin films on substrates from the evolution of the sin2 ψ curves as a function of applied strains. In the case of tungsten thin film, the value obtained is close to the bulk material one.
No takes yet. Share an insight, caveat, or question.
Renault et al. (1998) studied this question.