Key result
Second-order continuous-time sigma-delta modulator achieves ~114 dB SINAD for high-resolution ECG recordings.
Why the study?
High-Resolution Electrocardiograms are essential to detect low-amplitude ventricular signals called Late Potentials that standard ECGs cannot detect.
The proposed continuous-time ΣΔ modulator achieves high resolution and low power consumption, making it suitable for high-resolution ECG recordings to detect late potentials.
Answers are grounded in this paper and cite their sources.
May support low-power high-resolution ECG systems for late potentials; leaves open clinical validation before practice adoption.
High-Resolution Electrocardiograms (HRECGs) are essential to detect low-amplitude signals in the ventricles known as "Late Potentials" that cannot be detected with a standard ECG. This work presents the design of a fully-differential second-order Cascade-of-Integrators with Feedforward (CIFF) one-bit Continuous-Time (CT) ΣΔ modulator for HRECG recordings. The modulator incorporates two active RC loop filters, a summer, and a StrongARM latch, along with a single-bit resistive DAC. Integrator and summer circuits are designed using a differential operational transconductance amplifier (DOTA). The area of the pMOS input transistors in the first-stage integrator is increased compared to that of the second-stage integrator and summer to reduce flicker noise. The StrongARM latch is implemented without using a preamplifier, leading to a reduction in area and power dissipation. The designed ΣΔ Modulator (ΣΔΜ) circuit achieves a high Signal-to-Noise And Distortion ratio (SINAD) and resolution through an optimal design approach and a higher oversampling ratio (OSR). The proposed ΣΔM architecture is implemented using the MATLAB delta-sigma toolbox at the system-level and the Cadence Virtuoso EDA tool at 0.18µm CMOS technology at the circuit-level. The simulated performance parameters are validated at behavioral, macromodel, and circuit levels. To measure ECG signals of 150Hz bandwidth, a 300 kHz sampling frequency ( ) is used, resulting in an OSR of 1000. The proposed design achieves a SINAD of 113.7dB and a resolution of 18.59 bits. The modulator's measured power consumption is 0.49mW, achieving Schreier's Figure-of-Merit (FoM) of 168.55 dB, occupying an active area of 0.582 mm2.
No takes yet. Share an insight, caveat, or question.
Kavitha et al. (2025) studied Cardiovascular Diseases (ECG recording). Second-order Continuous-Time Sigma-Delta Modulator was evaluated on Signal-to-Noise And Distortion ratio (SINAD) and resolution. The proposed second-order continuous-time sigma-delta modulator achieved a SINAD of 113.7 dB and a resolution of 18.59 bits for high-resolution ECG recordings.