Key result
A low OSR passive integrator-based DSM achieved an SNDR/DR of 56.36/63.1 dB, consuming 160 nW power and occupying 0.035 mm^2 with an energy efficiency of 14.9 fJ/conv.
Why the study?
Analog to digital converter circuit design for biomedical systems with multiple recording channels faces challenges in achieving high density and very low power consumption while maintaining target resolution without high oversampling ratios.
The proposed duty-cycled passive integrator-based delta-sigma modulator achieves high energy efficiency and low power consumption suitable for multi-channel biopotential recording systems.
May enable efficient biopotential recording in wearables; leaves open clinical translation pending in vivo validation.
Analog to digitalconverter circuit design for biomedical systems with multiple recording channels presents challenges in high density and very low power consumption. Passive integrator and loop-filter based delta-sigma modulators (DSMs) have been recently reported for ultra-low-power and highly energy-efficient data converters for multi-channel biopotential acquisition. However, these modulators rely on a very high oversampling ratio (OSR) to achieve the target resolution. Higher OSR leads to higher power consumption in the modulator and the digital low-pass and decimation filter succeeding the DSM. We present a low OSR passive integrator-based DSM in this work by relying on a duty-cycled resistor (DCR). DCR enables the realization of large time constants in the already passive loop-filter, with minimal area and overhead power consumption. This leads to design of DSMs that are highly area, power and energy-efficient, suitable for multi-channel biopotential recording systems. We demonstrate a second order, duty-cycled passive integrator based CTDSM in a 65 nm CMOS technology for a 10 kHz biopotential bandwidth. Measurement results show that the fabricated design achieves an SNDR/DR of 56.36/63.1 dB while consuming only 160 nW power with an OSR of 32 and occupies an area of 0.035 mm²with a state-of-the-art energy efficiency of 14.9 fJ/conv. In-vitro and in-vivo measurements are provided to further demonstrate the operation of the proposed DSM.
No takes yet. Share an insight, caveat, or question.
Somappa et al. (2021) studied this question. Low OSR passive integrator-based DSM with duty-cycled resistor was evaluated on SNDR/DR, power consumption, area, and energy efficiency. A low OSR passive integrator-based DSM achieved an SNDR/DR of 56.36/63.1 dB, consuming 160 nW power and occupying 0.035 mm^2 with an energy efficiency of 14.9 fJ/conv.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: