A novel electrochemical sensor concept, which enables detection of ppb-levels of Pb 2+ in water, is outlined. The sensor works on the principle of underpotential deposition of Pb onto a Cu electrode followed by measurement of the hydrogen evolution reaction (HER) current on the Pb upd -modified electrode surface. The degree of suppression of the HER current is correlated to the Pb upd coverage, which in turn depends on the Pb 2+ concentration in solution. Feasibility of achieving a detection limit of 10 ppb Pb 2+ in aerated DI water and tap water is demonstrated and the sensing response time is analyzed using diffusion-reaction calculations.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: