Answers are grounded in this paper and cite their sources.
BACKGROUND Outcome in patients treated with haemodialysis (HD) is influenced by the delivered dose of dialysis. The UK Renal Association (RA) publishes clinical practice guidelines which include recommendations for dialysis dose. The urea reduction ratio (URR) is a widely used measure of dialysis dose. AIM To determine the extent to which patients received the recommended dose of HD in the UK. METHODS All seventy-two UK renal centres submitted data to the UK Renal Registry (UKRR). Two groups of patients were included in the analyses: the prevalent patient population on 31st December 2010 and the incident patient population for 2010. Centres returning data on 65%) increased from 56% in 1998 to 86% in 2010. There was persistent variation observed between centres, with 19 centres attaining the RA clinical practice guideline in >90% of patients and 39 centres attaining the guideline in 70-90%. The overall proportion of prevalent patients with a URR >65% has continued to improve over time. CONCLUSIONS The delivered dose of HD for patients with established renal failure has increased over the last decade. Whilst the majority of UK patients achieved the target URR there was considerable variation between centres in the percentage of patients achieving the guideline.
No takes yet. Share an insight, caveat, or question.
Pyart et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: