Key result
Sapien 3 valve linked to ~97% lower 1-year CV mortality versus Sapien XT.
Why the study?
The Sapien 3 valve had not been compared to the Sapien XT valve in Korean patients undergoing TAVR to evaluate procedural and clinical outcomes.
Does the Sapien 3 valve reduce cardiovascular mortality at 1 year compared to the Sapien XT valve in Korean patients undergoing TAVR?
Cohort (n=189)
Does the Sapien 3 valve reduce cardiovascular mortality at 1 year compared to the Sapien XT valve in Korean patients undergoing TAVR?
In Korean patients undergoing TAVR, the Sapien 3 valve was associated with lower 1-year cardiovascular mortality and less paravalvular leakage compared to the Sapien XT valve, despite a smaller effective orifice area.
Answers are grounded in this paper and cite their sources.
May support Sapien 3 preference in Korean TAVR; leaves open randomized confirmation of mortality benefit.
BACKGROUND AND OBJECTIVES: The Sapien 3 (S3) valve has not been compared to the Sapien XT (SXT) valve in Korea. We compared procedural and clinical outcomes between the 2 devices. METHODS: A total of 189 patients who underwent transcatheter aortic valve replacement (TAVR) with S3 (n=95) or SXT (n=94) valve was analyzed. The primary endpoint was cardiovascular mortality at 1 year. The median follow-up duration was 438 days. RESULTS: The Society of Thoracic Surgeons score was similar between the 2 groups. The device success rate (90.4% vs. 97.9%; p=0.028) was higher in the S3 than in the SXT. The S3 showed significantly fewer cases of moderate or severe paravalvular leakage (PVL) (16.7% vs. 0.0%; p=0.001) than the SXT. However, effective orifice area (EOA) (2.07±0.61 vs. 1.70±0.49 cm²; p<0.001) was smaller in the S3. Multivariable Cox regression analysis showed the S3 was associated with significantly fewer cardiovascular mortality at 1 year compared to the SXT (5.4% vs. 1.1%; hazard ratio, 0.031; 95% confidence interval, 0.001-0.951; p=0.047). Periprocedural complication rates, composite of disabling stroke or all-cause mortality, all-cause mortality, and disabling stroke at 1 year were similar between the 2 groups. CONCLUSIONS: Cardiovascular mortality was lower in the S3 group than in the SXT group over 1 year of follow-up. The reduction in PVL was attributed to the higher device success rate of TAVR with the S3 valve. However, the benefit of S3 obtained at the expense of reduced EOA should be meticulously re-evaluated in larger studies during long-term follow-up.
No takes yet. Share an insight, caveat, or question.
Kook et al. (2020) conducted a cohort in Transcatheter aortic valve replacement (n=189). Sapien 3 (S3) valve vs. Sapien XT (SXT) valve was evaluated on Cardiovascular mortality at 1 year (HR 0.031, 95% CI 0.001-0.951, p=0.047). The Sapien 3 valve was associated with significantly lower 1-year cardiovascular mortality compared to the Sapien XT valve (1.1% vs. 5.4%; HR 0.031; 95% CI 0.001-0.951; p=0.047).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: