Why the study?
The SAPIEN 3 addressed limitations of the SAPIEN XT, but whether these altered features translated into improved real-world outcomes after transfemoral TAVI required evaluation.
Does the SAPIEN 3 valve improve survival and reduce complications compared to the SAPIEN XT valve in patients undergoing transfemoral TAVI?
Does the SAPIEN 3 valve improve survival and reduce complications compared to the SAPIEN XT valve in patients undergoing transfemoral TAVI?
Answers are grounded in this paper and cite their sources.
The newer-generation SAPIEN 3 valve improves 1-year survival and reduces paravalvular leak and stroke compared to SAPIEN XT, though at the cost of increased permanent pacemaker implantation.
BACKGROUND: The SAPIEN 3 (S3) addresses several limitations of the SAPIEN XT (SXT) for the performance of transfemoral (TF-) balloon expandable transcatheter aortic valve implantation (TAVI). OBJECTIVES: We aimed to determine whether their altered features translate into improved outcomes in a real-world TF-TAVI patient population. METHODS: Data for 3,314 patients were extracted from the European registries SOURCE-XT and SOURCE-3. Patients were propensity-score (PS) matched (n = 1,169/group). RESULTS: In the PS matched comparison, device success was higher in the S3 (99.2%) compared to the SXT group (98.2%; p = .04). S3 patients experienced a lower rate of procedural death (0.7 vs. 2.6%; p = .0004), moderate/severe paravalvular leakage (PVL; 1.4 vs. 5.5%; p < .0001), and procedure-related stroke (1.2 vs. 2.4%; p = .04) while higher rates of mean aortic valve gradients ≥20 mmHg, and new permanent pacemaker implantations were seen. At 30 days a lower rate of all-cause mortality was seen (2.1% vs. 4.3%; p = .003), which was preserved after 1 year (10.7% vs. 14.9%; p = .002). A Cox regression predicting 1-year mortality resulted in a hazard ratio of 0.684 in favor of S3 (p = .0026). The same was true of stroke (2.8% vs. 5.7%; p = .0007), and moderate/severe PVL (2.7 vs. 7.3%; p = .0002) at 1 year. The rate of new pacemaker implantations (13.6% vs. 9.5%; p = .001) and NYHA III/IV (12.8 vs. 8.6%; p = .004) was higher with the S3. CONCLUSIONS: The improved features of the S3 appear to translate into improved survival and reduced rates of adverse complications, with the exception of a higher rate of new pacemaker implantations.
No takes yet. Share an insight, caveat, or question.
Schymik et al. (2019) studied this question.