Answers are grounded in this paper and cite their sources.
The purpose of this study was to identify potential BI-RADS 3 mass descriptors on breast magnetic resonance imaging by systematically defining positive predictive values (PPV). In a blinded retrospective review of BI-RADS 4 masses, reader 1 identified 132 masses and reader 2 identified 76 masses. PPV for mass descriptors and for descriptor combinations was determined. No mass descriptor resulted in a PPV ≤2% (BI-RADS 3 threshold). Descriptors with the lowest PPVs were circumscribed margin (8%), rim internal enhancement and persistent kinetics (13% each), and oval shape (15%). The results demonstrate the difficulty in transferring the theoretical concept of lesion surveillance to systematic clinical use.
No takes yet. Share an insight, caveat, or question.
Price et al. (2017) studied this question.