Key result
Pericardial patch augmentation for BAV repair yields 10% grade I AR at 4.2 years.
Why the study?
Reoperation rates after repair of bicuspid aortic valves are higher than for mitral valve reconstruction, and patch augmentation has shown satisfactory results for tricuspid aortic valves.
Does pericardial patch augmentation improve valve competence in patients with incompetent bicuspid aortic valves?
Observational (n=40)
Does pericardial patch augmentation improve valve competence in patients with incompetent bicuspid aortic valves?
Pericardial patch augmentation provides reliable early and midterm competence for reconstructed bicuspid aortic valves.
Patch augmentation may aid bicuspid aortic valve repair in selected patients; leaves open durability and comparative efficacy questions.
OBJECTIVE: Reoperation rates after repair of bicuspid aortic valves are higher than for mitral valve reconstruction. Satisfactory results have been reported for patch augmentation for tricuspid aortic valves. We have applied this technique for the repair of bicuspid aortic valves. METHODS: Autologous pericardium is sutured to the free edge of the prolapsing bicuspid leaflet. A large coaptation surface is created and competence of the bicuspid valve is achieved. Forty patients underwent reconstruction of their bicuspid aortic valves by pericardial patch augmentation. Patients were followed up at regular intervals by echocardiography in yearly intervals. RESULTS: There were no perioperative deaths. One year postoperatively, one patient died due to endocarditis. Seven patients (17.5%) had aortic regurgitation grade I, and the other 33 patients had non or trivial aortic regurgitation at discharge. At 4.2+/-3.1 years postoperatively, only four patients (10%) had aortic regurgitation grade I. There were no cases of progression of regurgitation. Planimetric effective orifice areas ranged above 2 cm2. Mean aortic gradients dropped from 8.2+/-4.8 mmHg at discharge to 3.8+/-3 at four years and the mean height of coaptation surface from 14.7+/-2mm to 12.3+/-4, respectively. CONCLUSIONS: The pericardial patch augmentation technique increases coaptation surface, and thus provides reliable early and midterm competence of reconstructed bicuspid aortic valves.
No takes yet. Share an insight, caveat, or question.
Doss et al. (2008) conducted an observational in incompetent bicuspid aortic valves (n=40). Pericardial patch augmentation was evaluated on aortic regurgitation grade I at 4.2 years. Pericardial patch augmentation for bicuspid aortic valve repair resulted in no perioperative deaths and only 10% of patients having grade I aortic regurgitation at 4.2 years postoperatively.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: