Answers are grounded in this paper and cite their sources.
An experimental study of transverse hydrogen injection and combustion behind a rearward-facing step into a Mach 2 airflow was conducted in an electrically heated (not vitiated), continuous-flow facility to evaluate the effects of initial conditions (temperature, pressure, and equivalence ratio), and analyze the interactions between mixing and combustion in supersonic, reacting flows. Neither mixing nor reaction rates dominate in this particular regime, thus the use of initial conditions to scale fuel mixing (i.e., dynamic pressure ratio) has to be modified by a descriptor that includes the effects of combustion on the flow conditions at the fuel injection station. Combustor inlet static pressure was varied from 0.25 to 0.5 atm, and total temperature from 300 to 850 K. Injector configurations include both single and staged injection with injectors of 1 and 1.5 mm diam, transverse to the airflow, behind a 5-mm rearward-facing step. Images of visible flame emission distribution at several temperatures correlated with pressure and temperature measurements are used to describe the coupling between fluid dynamics and chemical kinetics, discussed in terms of a characteristic global Damkohler number (ratio of chemical reaction rate to turbulent mixing rate). A proposed modification to mixing scaling with dynamic pressure ratio in the presence of heat release effects is presented.
No takes yet. Share an insight, caveat, or question.
Segal et al. (1995) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: