Key result
Coherent Sine Burst Electroporation PFA achieves ~78% chronic isolation at 6 months with low complications.
Why the study?
Challenges and opportunities remain for improvement of pulsed field ablation for atrial fibrillation.
Does the Coherent Sine Burst Electroporation (CSE) PFA system achieve durable pulmonary vein isolation in patients with atrial fibrillation undergoing de novo ablation?
Does the Coherent Sine Burst Electroporation (CSE) PFA system achieve durable pulmonary vein isolation in patients with atrial fibrillation undergoing de novo ablation?
Answers are grounded in this paper and cite their sources.
The novel Coherent Sine Burst Electroporation PFA system demonstrated durable isolation of pulmonary veins with a low complication rate and high freedom from atrial arrhythmias at 6 months in patients with AF.
BACKGROUND: Challenges or opportunities remain for improvement of pulsed field ablation (PFA) for atrial fibrillation (AF). OBJECTIVE: BURST-AF evaluated safety and lesion durability of a novel PFA system, Coherent Sine Burst Electroporation (CSE). METHODS: Patients with AF who failed ≥ 1 antiarrhythmic drug and undergoing de novo ablation were included. The CSE system includes a PFA generator and stylet-configurable catheter (circular, linear, focal). Pulmonary veins (PVs) were isolated with overlapping circular PFA applications. Ablation of additional lesions (posterior wall [PW]/cavotricuspid isthmus [CTI]) was performed at investigator discretion. Acute end point was isolation of PVs after a 20-minute waiting period. Chronic end point was isolation of PVs, bidirectional block (CTI), and/or absence of PW electrical activity at remap. Freedom from > 30 seconds of atrial arrhythmias was evaluated till 6 months. RESULTS: A total of 90 patients were enrolled (54% men, 62 years old, 60% paroxysmal AF). Targeted PVs (344) were isolated with 6.5 ± 1.7 PFA lesions/PV. PFA lesions for CTI and PW were 8.3 ± 4.7 and 14.4 ± 3.9, respectively. Procedure, catheter dwell, and fluoroscopy times were 93 ± 28 minutes, 54 ± 28 minutes, and 13.3 ± 5.5 minutes, respectively. Per PV isolation was 94.1% (317/337), and per patient isolation was 78.4% (69/88). Additional lesion set durability was 94.4% (102/108). At 6-month follow-up, 92.6% (63/68 patients) were free from atrial arrhythmias. One primary safety event of renal insufficiency was reported. CONCLUSION: CSE PFA system durably isolated PVs, PW, and CTI with a low rate of complications in this first-in-human study. (CSE System Pilot Study in Patients with Atrial Fibrillation - BURST-AF, NCT05572047).
No takes yet. Share an insight, caveat, or question.
Anić et al. (2025) studied Atrial fibrillation (n=90). Coherent Sine Burst Electroporation (CSE) pulsed field ablation system was evaluated on Chronic isolation of pulmonary veins, bidirectional block, and/or absence of posterior wall electrical activity at remap. The Coherent Sine Burst Electroporation PFA system achieved 78.4% per-patient chronic isolation and 92.6% freedom from atrial arrhythmias at 6 months with a low rate of complications.
Synapse has enriched 10 related papers. Consider them for comparative context: