Answers are grounded in this paper and cite their sources.
The author reports optical detection of singlet oxygen production accompanying continuous-wave (CW) laser irradiation of subcutaneous murine tumors at 630 nm following prior intraperitoneal injection of a Photofrin II sensitizer. The detection method is optical, remote, and, thus, noninvasive. Chopping of the incident laser beam was required in order to separate the spectrally discrete, time-delayed, singlet oxygen emission from the dominant, spectrally diffuse, coherent background provided by the combination of sensitizer infrared fluorescence and tissue-related autofluorescence. Using the infrared fluorescence to provide a reference, the singlet oxygen emission is shown to be given directly by the frequency-dependent quadrature component of the detector output. Maximum detector quadrature output for the in vivo case was obtained for a chopping frequency between 10 and 20 kHz. The spectral variation of the emission from the tumor was obtained and identified as that characteristic of singlet oxygen.
No takes yet. Share an insight, caveat, or question.
J. G. Parker (1987) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: