Why the study?
Accuracy of intra-arterial pressure readings depends on patients' clinical conditions and clinicians' knowledge and skills in device use, requiring guidance for nurses.
Highlights the importance of anatomical site, patient positioning, and vasoactive medications on the accuracy of intra-arterial pressure monitoring waveforms.
Emphasizes clinician skill in accurate intra-arterial monitoring; leaves open need for prospective validation before practice change.
Q: When monitoring arterial pressure using an intra-arterial pressure device, what do nurses need to know to ensure accuracy of readings?With the advent of disposable pressure transducer technology, accuracy affecting intra-arterial pressure readings is now limited to patients’ clinical conditions and clinicians’ knowledge and skills in the use of the intra-arterial pressure monitoring device. Some of the most common elements affecting accuracy of intra-arterial pressure readings include anatomical sites, peripheral vascular diseases, and use of vasoactive medications. The knowledge, experience, and skills of clinicians in leveling and zeroing pressure transducers; variations in patient position relative to the transducers; and waveform configurations also need to be considered in ongoing intra-arterial pressure measurement.Intra-arterial pressure monitoring is designed to measure systemic pressure as close to the heart as possible. The best way to measure true systemic pressure is through the use of a central aortic pressure catheter, which can only be accomplished during cardiac surgery or with an intra-aortic balloon catheter. As arterial pressure monitoring sites go from central to peripheral, changes in waveform configurations and readings occur (Figure 1). When arterial pulse waveforms are recorded from sites distal to the central aorta (for example, the dorsalis pedis), the systolic portion (anacrotic limb) becomes peaked and narrowed with increased amplitude. As a result, the systolic blood pressure in distal sites will be significantly higher than that recorded from a more central site. The diastolic portion of the waveform may display a secondary (reflectance) wave, as the monitoring site becomes more distal to the central aorta. The dicrotic notch becomes less defined as the monitoring site is moved toward the periphery. These changes could also be intensified with significant doses of vasodilators or vasopressors. With vasodilators, the waveform takes on a more central appearance (for example, the femoral arterial waveform). With vasoconstrictors, the systolic pressure component becomes exaggerated due to enhanced resistance in the peripheral arteries. In infants, however, the change in waveform from central aortic to peripheral sites may not be as pronounced due to age and shorter limbs.Advanced technology in disposable transducer systems ensures accurate calibration and low drift from zero. Transducer failures are rare. There are, however, steps nurses can take to ensure precision and accuracy of the intra-arterial pressure monitoring system:Control and monitoring of intra-arterial pressure device is predominantly within nursing’s domain. To ensure optimum pharmacological and mechanical intervention on changes in systemic pressure, it is crucial that nurses be aware of all factors affecting accuracy of monitoring.This article is based on the protocol “Arterial Pressure Monitoring” by Flerida Imperial-Perez and Marion McRae. It was taken from the Hemodynamic Monitoring series of AACN’s Protocols for Practice. Protocols can be obtained from AACN, 101 Columbia, Aliso Viejo, CA 92656-1491, (800) 899-AACN, (949) 362-2000. $11.01, AACN members; $12.95, nonmembersThis article was first published in Critical Care Nurse April 1999.
No takes yet. Share an insight, caveat, or question.
Imperial-Perez et al. (2002) conducted a review in Intra-arterial pressure monitoring. Intra-arterial pressure monitoring was evaluated. Intra-arterial pressure monitoring accuracy depends on anatomical sites, patient conditions, and clinicians' skills in leveling and zeroing transducers.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: