Key result
Minimally invasive transaxillary combined aortic valve and ascending aortic replacement using the RAM system was feasible and safe, allowing successful completion without sternotomy.
Why the study?
Minimally invasive approaches for combined aortic valve and ascending aortic surgery remain challenging and require evaluation for feasibility and safety.
Case Report (n=1)
No
This first-in-human case report demonstrates the initial feasibility and safety of using an automated suturing device (RAM system) for combined transaxillary endoscopic aortic valve and ascending aorta replacement, offering a potential sternotomy-sparing approach for complex aortic pathology.
Answers are grounded in this paper and cite their sources.
May not alter sternotomy standards yet; leaves open transaxillary feasibility for prospective validation.
Background: Minimally invasive approaches for combined aortic valve and ascending aortic surgery remain challenging. We report a case of utilizing a transaxillary approach (TAX) in combination with the RAM® system. Methods: A 65-year-old male presented with exertional angina and palpitations. He reported a one-year history of dizziness. Diagnostics revealed severe aortic regurgitation due to a calcified bicuspid aortic valve and an ascending aortic aneurysm measuring 57 × 54 mm. Left ventricular ejection fraction was reduced to 42%. Coronary artery disease was excluded. Surgery was performed via a right transaxillary mini-thoracotomy (3rd intercostal space) using endoscopic visualization. Cardiopulmonary bypass was established through femoral cannulation. After aortic cross-clamping and cardioplegic arrest, the bicuspid valve was excised and replaced with a bioprosthesis. A supracoronary ascending aortic replacement was performed using a Dacron graft. The RAM® system was used for annular suturing and proximal anastomosis, with automated fastener fixation. Results: The patient was extubated on postoperative day 1 and transferred to intermediate care on day 2. Postoperative recovery was uneventful, with no neurological deficits, bleeding, or other complications. Discharge occurred on postoperative day 9 in stable condition. Conclusions: This case highlights the feasibility and safety of a minimally invasive transaxillary approach for combined aortic valve and ascending aortic replacement using the RAM® system. This technique may expand the surgical armamentarium for complex aortic pathology while avoiding sternotomy. Further studies are required to evaluate reproducibility, long-term outcomes, and broader applicability.
No takes yet. Share an insight, caveat, or question.
Josic et al. (2026) conducted a case report in Severe aortic regurgitation and ascending aortic aneurysm (n=1). Transaxillary endoscopic aortic valve and ascending aorta replacement using the RAM system was evaluated on Procedural success and postoperative recovery. Minimally invasive transaxillary combined aortic valve and ascending aortic replacement using the RAM system was feasible and safe, allowing successful completion without sternotomy.
Synapse has enriched 10 related papers. Consider them for comparative context: