Answers are grounded in this paper and cite their sources.
Discordant thyroid function tests sometimes make it difficult to make clinical decisions. This clinical problem must be understood to avoid misdirected investigation or incorrect therapeutic intervention. In serum, 99.95% of thyroxine (T4) and 99.5% of triiodothyronine (T3) are bound by three carrier proteins: T4-binding globulin (TBG), transthyretin (TTR), and thyroid hormone binding serum prealbumin (TPBA).[1] TBG has a greater affinity for thyroid hormones, making the predominant serum carriers for T4 and T3. Because T4 is highly bound to serum proteins, alternations in the levels of these proteins or their binding characteristics can significantly alter the concentration of total hormones. In pregnancy, TBG levels upsurge as a result of estrogen-induced increased hepatic synthesis, together with reduced degradation. Estrogen, raloxifene, tamoxifen, mitotane, fluorouracil, methadone, and heroin are the drugs that can cause increased serum TBG concentrations.[1] In contrast, androgens, chronic glucocorticoid therapy, and nicotinic acid have all been shown to inhibit TBG synthesis.[1] Thyroid-stimulating hormone (TSH) is a two-subunit glycoprotein. The α subunit is structurally similar to follicle-stimulating hormone, luteinizing hormone, and human chorionic hormone, but the β subunit confers its specificity. Each individual has a genetically determined set point for the TSH-FT4 relationship. TSH levels peak just before nocturnal sleep, which is lost early in the nonthyroidal illness, and nadir in the late afternoon.[2] The presence of human anti-animal antibodies (HAAs) in a patient’s serum can interfere with TSH measurement if directed against the assay antibodies; thus, an HAA that blocks TSH binding will result in a falsely low TSH readout; contrariwise, an HAA that is capable of cross-linking leading to a falsely high TSH.[3,4] Heterophile antibodies are weak polyspecific antibodies capable of causing negative or positive interference.[5] Such interference in the TSH assay can be seen in cases of Graves’ disease and patients with positive rheumatoid factor. Macro-TSH is a macromolecule due to the complex binding of TSH to immunoglobulins, which results in increased TSH. Even though macro-TSH has poor biological activity and circulates longer, it retains the ability to react with antibodies used in immunoassays, causing falsely elevated results. Patients on irregularly treated thyroid medications, illness, and many other causes can mislead TSH levels [Table 1].Table 1: Clinical situations where only the thyroid-stimulating hormone test may be misleadingThe most commonly employed technique for determining TT4 and TT3 is competitive immunoassay, using polyclonal or monoclonal capture antibodies. Enzyme-linked immunosorbent assay is the most widely used assay. Other technologies, such as liquid chromatography-tandem mass spectroscopy (LC-MS/MS), have been applied to provide greater specificity and less analytic interference.[3,5] Due to common alterations in serum TBG levels, TT4 and TT3 are generally not used as standard tests in clinical practice. As the free hormone is biologically active, techniques are required to permit either direct measurements or estimation of the serum free hormone levels. Direct methods for measuring FT4 and FT3 include equilibrium dialysis, ultrafiltration, and gel filtration to separate the free hormones from their binding proteins. The LC-MS/MS technique to measure FT4 levels provides high specificity, hence its use as a reference assay.[6,7] FT4 (and less frequently FT3) to be overestimated in dominantly inherited genetic variants of albumin, e.g. familial dysalbuminemic hyperthyroxinemia (FDH) and transthyretin-associated hyperthyroxinemia, which alter its affinity for iodothyronines, particularly in “one-step” analog hormone assays.[8] COMMON ABNORMAL PATTERNS Pattern 1 Raised T4/T3 and nonsuppressed TSH. Assay interference TSH measurements HAAs in a patient’s serum can cause negative and positive interference; the same can be true of heterophilic antibodies. Free T4/T3 measurement Fractionated and unfractionated heparin can both cause an artificial elevation of FT4 and FT3 by displacement of carrier proteins Anti-iodothyronine antibodies which bind to tracer HHA or heterophilic antibodies block the assay antibody Genetic variants – Dominantly inherited FDH can cause FT4 to be overestimated in one-step analog hormone assays TBG deficiency can cause erroneously raised FT4 but genuinely low TT4. Thyroxin therapy, poor adherence Drug treatment Amiodarone - elevated FT4, normal TSH and FT3 Glucocorticoids, propranolol, iodinated contrast media, or medications can reduce T4 to T3 conversation. Nonthyroidal illness Resistance to thyroid hormone beta and TSH-secreting pituitary tumors. Pattern 2 Raised TSH, normal T4. Assay interference Subclinical hypothyroidism T4 treatment Mild congenital hypothyroidism (TSH resistance, GNAS, or NHX2.1 mutation). Pattern 3 Low T4 and normal TSH. Isolated TSH deficiency Central hypothyroidism or nonthyroidal illness. How to approach Figure 1 elaborates on approach to the patient with discordant thyroid function test results, including when to consider investigations relating to rare genetic disorders.
No takes yet. Share an insight, caveat, or question.
Amin et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: