This is the authors' abstract. We don't add key points for this paper.
Accurate monitoring of exposure to organic vapors, such as acetone, is an important part of maintaining a safe working environment and adhering to long‐ and short‐term exposure limits. Here, a novel acetone vapor detection system is described based on the use of a reactive chiral dopant in a nematic liquid crystal thin film, which can accurately monitor the total exposure over a given time frame through changes in the reflection band of the film. It is found that films exposed to 1000 parts per million by volume (ppmv) of acetone vapor for 2 h exhibit a shift in reflection band of 12 nm, with smaller shifts observed at lower concentrations of acetone. Such sensors have potential applications in industrial hygiene.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Cachelin et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: