Answers are grounded in this paper and cite their sources.
We present a technique to achieve ultrathin Descemet-stripping automated endothelial keratoplasty (DSAEK). Using a simple method of controlling artificial anterior chamber pressure and drying the corneal surface, it was possible to thin the donor cornea at a rate of 11 μm a minute. When the donor cornea was between 500 μm and 510 μm, a single pass was made using a 350 μm microkeratome head followed by a peripheral dissection. The resulting mean graft thickness was 83.2 μm ± 14.9 (SD) (range 50 to 98 μm) with a mean peripheral graft edge thickness of 106.8 ± 10.9 μm (range 90 to 120 μm). There were no surgical complications, and all grafts remained attached. This is a reliable method for preparing ultrathin donor corneal lenticules for DSAEK in the operating room or eye bank without using multiple microkeratome heads or risking double passes.
No takes yet. Share an insight, caveat, or question.
Romano et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: