Key result
3D speckle tracking echocardiography shows limited technical feasibility for assessing fetal myocardial deformation.
Why the study?
Fetal cardiac function can be quantified by different methods, but this is the first approach using real three-dimensional speckle tracking echocardiography to assess fetal cardiac strain parameters.
Is three-dimensional speckle tracking echocardiography feasible for assessing myocardial deformation parameters in healthy fetuses?
Observational (n=8)
Is three-dimensional speckle tracking echocardiography feasible for assessing myocardial deformation parameters in healthy fetuses?
Three-dimensional speckle tracking echocardiography for assessing fetal myocardial deformation is currently only feasible in individual cases and requires further technical development.
Answers are grounded in this paper and cite their sources.
May support 3D fetal speckle tracking feasibility; hypothesis-generating and requires validation before clinical use.
OBJECTIVES: Fetal cardiac function can be quantified by different methods. This is the first approach of real three-dimensional(3 D)-based speckle tracking echocardiography in the fetus to assess different cardiac strain parameters. METHODS: We present preliminary results of fetal global myocardial strain analyses. For fetal echocardiography a Toshiba Artida system was used. Based on an apical or basal four-chamber view of the fetal heart, raw data volumes with a high temporal resolution were acquired and digitally stored. RESULTS: 8 individual healthy fetuses with an echocardiogram performed between 21 and 37 weeks of gestation were included. The mean temporal resolution was 31.2 ± 4.3 volumes per second (vps). Basic parameters such as longitudinal and circumferential strain as well as advanced 3 D myocardial motion patterns such as area strain, rotation, twist and torsion were assessed. CONCLUSION: Currently the assessment of fetal myocardial deformation parameters by 3 D speckle tracking seems to be technically feasible only in individual cases. In the future further development of this technique is necessary to improve its application in fetal echocardiography.
No takes yet. Share an insight, caveat, or question.
Enzensberger et al. (2014) conducted an observational in Healthy fetuses (n=8). Three-dimensional (3D) speckle tracking echocardiography was evaluated on Feasibility of assessing fetal global myocardial strain parameters. Three-dimensional speckle tracking echocardiography to assess fetal myocardial deformation parameters was technically feasible only in individual cases among 8 healthy fetuses.
Synapse has enriched 10 related papers. Consider them for comparative context: