Key result
Fetal 2D myocardial strain at 60 fps yields similar global longitudinal strain versus 30 fps.
Why the study?
Does frame rate (60 fps vs 30 fps) influence longitudinal strain analysis assessed by 2D speckle tracking in fetal echocardiography?
Observational (n=101)
Does frame rate (60 fps vs 30 fps) influence longitudinal strain analysis assessed by 2D speckle tracking in fetal echocardiography?
Myocardial 2D strain analysis by wall-motion tracking in fetal echocardiography is feasible and relatively independent of acquisition frame rates between 30 and 60 fps.
Answers are grounded in this paper and cite their sources.
Comparable fetal strain at 30 versus 60 fps supports standard acquisitions; leaves open optimal settings for routine use.
BACKGROUND: Frame rates (FR) used for strain analysis assessed by speckle tracking in fetal echocardiography show a considerable variation. The aim of this study was to investigate the influence of the FR on strain analysis in 2D speckle tracking. METHODS: Fetal echocardiography was performed prospectively on a Toshiba Aplio 500 system and a Toshiba Artida system, respectively. Based on an apical or basal four-chamber view of the fetal heart, cine loops were stored with a FR of 30 fps (Aplio 500) and 60 fps (Artida/Aplio 500). For both groups (30fps and 60fps), global and segmental longitudinal peak systolic strain (LPSS) values of both, left (LV) and right ventricle (RV), were assessed by 2D wall-motion tracking. RESULTS: A total of 101 fetuses, distributed to three study groups, were included. The mean gestational age was 25.2±5.0 weeks. Mean global LPSS values for RV in the 30 fps group and in the 60 fps group were -16.07% and -16.47%, respectively. Mean global LPSS values for LV in the 30 fps group and in the 60 fps group were -17.54% and -17.06%, respectively. Comparing global and segmental LPSS values of both, the RV and LV, did not show any statistically significant differences within the two groups. CONCLUSION: Performance of myocardial 2D strain analysis by wall-motion tracking was feasible with 30 and 60 fps. Obtained global and segmental LPSS values of both ventricles were relatively independent from acquisition rate.
No takes yet. Share an insight, caveat, or question.
Enzensberger et al. (2017) conducted an observational in Fetal echocardiography (n=101). 60 fps frame rate vs. 30 fps frame rate was evaluated on Global longitudinal peak systolic strain (LPSS) of the right ventricle. Fetal myocardial 2D strain analysis using a 60 fps frame rate yielded similar global longitudinal peak systolic strain compared to 30 fps for the right and left ventricles.
Synapse has enriched 10 related papers. Consider them for comparative context: