Key result
TTE and TEE yield smaller aortic annular diameters than MSCT in TAVI candidates.
Why the study?
In severe aortic stenosis patients referred for TAVI, the differences in aortic annular diameter measurements by TTE, TEE, and MSCT and their impact on prosthetic valve selection remain unclear.
Does aortic annular diameter measured by TTE and TEE differ from MSCT in severe aortic stenosis patients referred for TAVI?
Does aortic annular diameter measured by TTE and TEE differ from MSCT in severe aortic stenosis patients referred for TAVI?
Answers are grounded in this paper and cite their sources.
Aortic annular diameter measurements by TTE and TEE are smaller than those by MSCT, highlighting the need for comprehensive multimodality evaluation when selecting prosthetic valve size for TAVI.
In severe aortic stenosis patients referred for TAVI, the aortic annular diameter derived from TTE and TEE measurements are smaller than that from MSCT.In the absence of a gold standard, selection of prosthetic valve type in TAVI procedure should rely on comprehensive considerations, which is of importance to get good clinical results for severe aortic stenosis patients underwent TAVI.
No takes yet. Share an insight, caveat, or question.
Qi et al. (2017) studied this question. Aortic annular diameters derived from TTE and TEE are smaller than those from MSCT in patients with severe aortic stenosis referred for TAVI.
Synapse has enriched 10 related papers. Consider them for comparative context: