Key result
Peak and late NaV1.5 currents linked to Brugada and long QT syndrome disease penetrance.
Why the study?
Accurately predicting the impact of rare nonsynonymous SCN5A variants on disease risk is an important goal in precision medicine due to their association with multiple arrhythmia disorders and presence in unaffected individuals.
Do in vitro electrophysiological parameters of SCN5A variants correlate with disease penetrance for Brugada syndrome and long QT syndrome?
Systematic Review
Do in vitro electrophysiological parameters of SCN5A variants correlate with disease penetrance for Brugada syndrome and long QT syndrome?
Effect estimate: ρ=-0.44 (Brugada) and ρ=0.37 (long QT)
p-value: p=<0.001
In vitro electrophysiological parameters of SCN5A variants correlate significantly with disease penetrance for Brugada syndrome and long QT syndrome, which can aid in variant classification.
Supports NaV1.5 current data for SCN5A variant classification in Brugada and long QT syndromes; extends functional evidence linking currents to penetrance.
Background: Accurately predicting the impact of rare nonsynonymous variants on disease risk is an important goal in precision medicine. Variants in the cardiac sodium channel SCN5A (protein Na V 1.5; voltage-dependent cardiac Na+ channel) are associated with multiple arrhythmia disorders, including Brugada syndrome and long QT syndrome. Rare SCN5A variants also occur in ≈1% of unaffected individuals. We hypothesized that in vitro electrophysiological functional parameters explain a statistically significant portion of the variability in disease penetrance. Methods: From a comprehensive literature review, we quantified the number of carriers presenting with and without disease for 1712 reported SCN5A variants. For 356 variants, data were also available for 5 Na V 1.5 electrophysiological parameters: peak current, late/persistent current, steady-state V1/2 of activation and inactivation, and recovery from inactivation. RESULTS: We found that peak and late current significantly associate with Brugada syndrome ( P <0.001; ρ=−0.44; Spearman rank test) and long QT syndrome disease penetrance ( P <0.001; ρ=0.37). Steady-state V1/2 activation and recovery from inactivation associate significantly with Brugada syndrome and long QT syndrome penetrance, respectively. Continuous estimates of disease penetrance align with the current American College of Medical Genetics classification paradigm. Conclusions: Na V 1.5 in vitro electrophysiological parameters are correlated with Brugada syndrome and long QT syndrome disease risk. Our data emphasize the value of in vitro electrophysiological characterization and incorporating counts of affected and unaffected carriers to aid variant classification. This quantitative analysis of the electrophysiological literature should aid the interpretation of Na V 1.5 variant electrophysiological abnormalities and help improve Na V 1.5 variant classification.
No takes yet. Share an insight, caveat, or question.
Kroncke et al. (2018) conducted a systematic review in Brugada syndrome and long QT syndrome. SCN5A (Na V 1.5) variant electrophysiological parameters was evaluated on Disease penetrance of Brugada syndrome and long QT syndrome (ρ=-0.44 (Brugada) and ρ=0.37 (long QT), p=<0.001). Peak and late Na V 1.5 currents significantly associate with Brugada syndrome (P<0.001; ρ=-0.44) and long QT syndrome disease penetrance (P<0.001; ρ=0.37).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: