Key result
Consumer fitness trackers accurately measure postoperative heart rate vs ECG with ~5% error.
Why the study?
Further validations of heart rate measurement accuracy by consumer-grade fitness trackers in hospitalized patients are essential but lacking to date.
Do consumer-grade fitness trackers accurately measure heart rate compared to electrocardiography in postoperative patients?
Observational (n=201)
Do consumer-grade fitness trackers accurately measure heart rate compared to electrocardiography in postoperative patients?
Consumer-grade fitness trackers provide accurate heart rate monitoring in hospitalized postoperative patients, with mean absolute error <5 beats per minute compared to ECG.
Answers are grounded in this paper and cite their sources.
Supports postoperative HR monitoring with fitness trackers; hypothesis-generating pending RCTs on outcomes and generalizability.
BACKGROUND: Over the recent years, technological advances of wrist-worn fitness trackers heralded a new era in the continuous monitoring of vital signs. So far, these devices have primarily been used for sports. OBJECTIVE: However, for using these technologies in health care, further validations of the measurement accuracy in hospitalized patients are essential but lacking to date. METHODS: We conducted a prospective validation study with 201 patients after moderate to major surgery in a controlled setting to benchmark the accuracy of heart rate measurements in 4 consumer-grade fitness trackers (Apple Watch 7, Garmin Fenix 6 Pro, Withings ScanWatch, and Fitbit Sense) against the clinical gold standard (electrocardiography). RESULTS: ≥0.94) coefficients, with a relative error as low as mean absolute percentage error <5% based on 1630 valid measurements. We identified confounders significantly biasing the measurement accuracy, although not at clinically relevant levels (mean absolute error<5 beats per minute). CONCLUSIONS: Consumer-grade fitness trackers appear promising in hospitalized patients for monitoring heart rate. TRIAL REGISTRATION: ClinicalTrials.gov NCT05418881; https://www.clinicaltrials.gov/ct2/show/NCT05418881.
No takes yet. Share an insight, caveat, or question.
Helmer et al. (2022) conducted an observational in Postoperative patients (n=201). Consumer-grade fitness trackers (Apple Watch 7, Garmin Fenix 6 Pro, Withings ScanWatch, and Fitbit Sense) vs. Electrocardiography was evaluated on Accuracy of heart rate measurements (mean absolute percentage error <5%). Consumer-grade fitness trackers accurately measured heart rate in postoperative patients compared to electrocardiography, with a mean absolute percentage error of <5%.