Answers are grounded in this paper and cite their sources.
Demonstrates reliable HbA1c measurement in frozen buffy coat samples, indicating stored biobank specimens can support retrospective metabolic analyses without impairing DNA yield.
Appropriately reliable estimates of the quantitative importance of various risk factors for chronic diseases and of the nature of any interactions between them may require epidemiologic studies involving several thousand “cases” of a disease. Blood-based epidemiologic studies on this scale can be facilitated by practicable methods for collection, storage, and analysis of very large numbers of samples. For example, although assessment of diabetic status using blood glucose concentration may require fasted samples, glycated hemoglobin (HbA1c) provides a measure of average glycemic control over the preceding months that can be determined reliably in nonfasted blood (1), which is more convenient for large-scale studies. HbA1c has, however, traditionally been measured in fresh whole blood, which has precluded its analysis in frozen samples stored in epidemiologic studies for future assays. In the present study, we investigated the measurement of HbA1c in frozen “buffy coat” samples (aliquots of white blood cells, taken from the plasma/red cell interface in centrifuged whole blood, which also inevitably contain some plasma and red cells) that might typically have been stored for the subsequent extraction of DNA. In addition, we assessed the effect of thawing and refreezing of samples for HbA1c measurement on DNA yield. HbA1c was measured in fresh whole blood, collected from 360 individuals with evidence of occlusive arterial disease and/or diabetes mellitus (2), by HPLC using a Biomen Hi-Auto1c HA-8121 analyzer and reagents and a calibrator linked to Biomen reference values. These whole-blood samples were then centrifuged, and buffy coat samples were taken off, stored at −40 °C for 4–5 months, and then thawed for remeasurement of HbA1c. The inter- and intraassay CVs were <3% for HbA1c quality-control percentages of ∼4.5% and 8.0%. Subsequent to these analyses (performed in 1996–1997), the method can be calibrated as traceable to the Diabetes Control and Complications Trial Reference Method, in accordance with the National Glycohemoglobin Standardization Program (3). To assess any effect on DNA yield of an extra freeze-thaw, 133 buffy coat samples (∼1 mL each) stored at −40 °C for 7 years were either thawed for immediate DNA extraction or thawed, refrozen for 2–3 months, and then thawed again for DNA extraction. DNA extraction was performed using Puregene reagents (Flowgen), and the DNA yield was quantified on a Jenway 6105 spectrophotometer. The HbA1c results obtained from stored buffy coat samples (HbA1c frozen) were highly correlated (r = 0.98) with those from fresh whole blood (HbA1c fresh). Values obtained from buffy coat samples tended to be slightly lower than those from fresh whole blood (overall mean ± SE, 7.4% ± 0.1% vs 7.6% ± 0.1%; 2P <0.0001). Regression analysis yielded the equation: HbA1c frozen = 0.95(HbA1c fresh) + 0.14%, indicating that the buffy coat measurement underestimated the absolute percentage by only 0.1% HbA1c at the lower end and by ∼0.5% HbA1c at the upper end of the range studied, as illustrated by the difference plot in Fig. 1. The percentage difference between the values was constant (3%) throughout the range studied. This slight difference in HbA1c values may be explained by interassay variability of the method, as suggested by quality-control results, which were, on average, 2–3% lower during measurement of the frozen buffy coat samples compared with fresh whole blood. Similar mean (± SE) yields of DNA were obtained in samples thawed once compared with samples thawed twice: 184 ± 15 vs 176 ± 13 μg (2P = 0.7). Difference plot comparing HbA1c (%) values in frozen buffy coat samples and fresh whole blood. Dashed line indicates mean difference between values for HbA1c (%) in buffy coat and whole-blood samples (n = 360 paired patient samples); dotted lines indicate the mean ± 2 SD. Equation for the regression line (thin solid line): y = −0.048x + 0.143%. These results demonstrate that the percentages of HbA1c can be determined reliably by HPLC in nonfasting, blood buffy coat samples frozen at −40 °C that might typically be stored for subsequent DNA extraction and analysis in an epidemiologic study. Thawing such samples to allow measurement of HbA1c does not appear to affect subsequent DNA yields. Because the samples for this study of HbA1c values were stored at −40 °C for months rather than years, further studies in samples stored for longer periods are needed to determine whether any deterioration of HbA1c occurs over time. However, recent evidence suggests that HbA1c is stable at −70 °C in whole blood for at least 1 year (4).
No takes yet. Share an insight, caveat, or question.
Youngman et al. (2002) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: