Key result
Surgical transcatheter valve deployment with a pericardial patch successfully treats severe mitral calcification without leak.
Why the study?
Management of severe mitral annulus calcification during combined valve replacement and coronary bypass surgery poses technical challenges requiring innovative bailout techniques.
Can a transcatheter valve be used as a bailout technique during complicated open mitral valve surgery with severe calcification?
Case Report (n=1)
No
Can a transcatheter valve be used as a bailout technique during complicated open mitral valve surgery with severe calcification?
A transcatheter valve can be successfully deployed surgically with a pericardial patch as a bailout technique for severe mitral annular calcification.
Answers are grounded in this paper and cite their sources.
May offer a bailout for severe mitral calcification; hypothesis-generating and needs prospective validation before adoption.
Here, we describe the case of a 62-year old woman who required aortic and mitral valve replacement plus coronary artery bypass grafting. Transoesophageal echocardiogram revealed stenosis of the aortic valve (Ao valve area, 0.9 cm(2); PG, 45 mmHg; MG, 25 mmHg) and a diseased calcified mitral valve with stenosis and regurgitation (mitral valve area, 1.1 cm(2); MG, 10 mmHg; RV, 25 ml; ERO, 12 mm(2)). The mitral annulus calcifications were very deep into the left atrium and the left ventricle muscle, around the full annulus circumference. We decided to avoid complete deep mitral annulus decalcification. The left atrium was surgically exposed, and we deployed a 26-mm Edwards SAPIEN XT endovalve through the left atriotomy. To prevent paravalvular leakage, we then used a pericardial patch to close the gap between the endovalve and the calcified mitral annulus. The postoperative echocardiogram showed perfect anchoring of the endovalve in the mitral annulus without any paravalvular leakage.
No takes yet. Share an insight, caveat, or question.
Astarci et al. (2013) conducted a case report in Aortic and mitral valve disease with severe mitral annulus calcification (n=1). Transcatheter valve implantation (26-mm Edwards SAPIEN XT) with pericardial patch during open surgery was evaluated on Postoperative echocardiogram findings (anchoring and paravalvular leakage). Deployment of a 26-mm Edwards SAPIEN XT transcatheter valve with a pericardial patch during open surgery successfully treated a heavily calcified mitral valve without paravalvular leakage.
Synapse has enriched 10 related papers. Consider them for comparative context: