Key result
Italian catheter ablations primarily target AF and utilize 3D mapping in ~62% of procedures.
Why the study?
The 2018 Italian Catheter Ablation Registry aimed to systematically describe the organization and procedures of catheter ablation centres in Italy.
Observational (n=15,714)
Yes
The 2018 Italian Catheter Ablation Registry demonstrates that atrial fibrillation is the most common ablation target and highlights a high adoption rate of 3D mapping and nonfluoroscopic navigation systems in Italian electrophysiology centres.
Answers are grounded in this paper and cite their sources.
Registry snapshot details Italian EP lab setups and AF ablation volumes; leaves open outcome associations and standardization needs.
AIMS: This report describes the findings of the 2018 Italian Catheter Ablation Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC). METHODS: The Italian Catheter Ablation Registry systematically collects data on the ablation procedures performed in Italy. Data collection was retrospective. A standardized questionnaire was completed by participating centres. RESULTS: We collected data on 15 714 catheter ablation procedures performed in Italy during 2018 in 94 electrophysiology centres. In most centres (75/94, 80%), a single electrophysiology laboratory was available, and a hybrid electrophysiology laboratory was available in 15% (14/94) of centres. In most (93%) centres, at least two electrophysiologists were involved in the catheter ablation procedures. In only 13 out of 94 (14%) electrophysiology laboratories, an anaesthesiologist assists every electrophysiology procedure; in most cases (74/94, 79%), an on-demand anaesthesiology service was available. On-site cardiothoracic surgery was reported in 43 out of 94 (46%) centres.Nonfluoroscopic navigation systems were available in most centres (88/94, 93%). Intracardiac echocardiography was used in 59 out of 94 (63%) electrophysiology laboratories. Atrial fibrillation (31%) was the most frequently treated ablation target, followed by atrioventricular nodal re-entrant tachycardia (20%) and cavo-tricuspid isthmus (15%). In 61.7% of all procedures, a 3D mapping system was used. In about one-third of procedures, a near-zero approach was performed. CONCLUSION: In most Italian electrophysiology centres, a single electrophysiology laboratory was available and at least two electrophysiologists were involved in the ablation procedures. An increasing number of procedures were performed by means of a nonfluoroscopic mapping system with a near-zero approach.
No takes yet. Share an insight, caveat, or question.
Stabile et al. (2021) conducted an observational in Arrhythmias requiring catheter ablation (n=15,714). Catheter ablation was evaluated on Procedural characteristics and ablation targets. Among 15,714 catheter ablation procedures in Italy in 2018, atrial fibrillation was the most frequent target, and 3D mapping systems were used in 61.7% of all procedures.