Why the study?
The accuracy of Logistic EuroSCORE, EuroSCORE II, and Society of Thoracic Surgeons scoring systems in predicting mortality after transcatheter aortic valve-in-valve implantations was not previously assessed.
How accurate are the Logistic EuroSCORE, EuroSCORE II, and STS scoring systems in predicting 30-day all-cause mortality in patients undergoing transcatheter aortic valve-in-valve implantations?
Observational (n=1,550)
Yes
How accurate are the Logistic EuroSCORE, EuroSCORE II, and STS scoring systems in predicting 30-day all-cause mortality in patients undergoing transcatheter aortic valve-in-valve implantations?
Answers are grounded in this paper and cite their sources.
Standard surgical risk scores significantly overestimate 30-day mortality in patients undergoing transcatheter aortic valve-in-valve procedures, though EuroSCORE II provides the best discrimination.
BACKGROUND: Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS). OBJECTIVE: The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all-cause mortality after transcatheter aortic valve-in-valve (ViV) implantations, which was not assessed before. METHODS: Using the Valve-in-Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30-day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination. RESULTS: Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (± 17.2), 14.59 (± 8.6), and 9.61 (± 8.51), respectively. All three risk scores overestimated 30-day mortality with ratios of 0.176 (95% CI 0.138-0.214), 0.342 (95% CI 0.264-0.419), and 0.536 (95% CI 0.421-0.651), respectively. 30-day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698. CONCLUSIONS: All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.
No takes yet. Share an insight, caveat, or question.
Aziz et al. (2018) conducted an observational in Degenerated surgically implanted aortic valves requiring transcatheter valve-in-valve implantation (n=1,550). Logistic EuroSCORE, EuroSCORE II, and STS risk scores vs. Observed mortality was evaluated on 30-day overall mortality (O/E ratio 0.342, 95% CI 0.264-0.419).