Key result
Prototype transesophageal focused ultrasound applicator successfully creates lesions in fresh porcine myocardium in vitro.
Why the study?
Catheter ablation for atrial fibrillation is effective but involves morbidity, high costs, and procedural time, motivating development of a non-invasive ultrasound applicator for cardiac ablation.
A novel transesophageal focused ultrasound applicator demonstrates in vitro feasibility for non-invasive cardiac ablation of atrial fibrillation.
In vitro feasibility supports further preclinical testing; leaves open translation to safe clinical use for AF ablation.
Atrial fibrillation (AF) is the most common type of arrhythmia, affecting more than 2.2 million Americans. One effective treatment is cardiac ablation, which shows a high rate of success in treating paroxysmal AF. As a prevailing modality for this treatment, catheter ablation using radiofrequency has been effective, but comes with measurable morbid- ity and significant costs and time associated with this procedure for permanent or persistent AF. To address these issues, an ultrasound applicator for cardiac ablation without surgical incisions or blood contact was designed, developed and evaluated in this study. To initially design a transesophageal applicator using therapeutic ultrasound capable of creating atrial lesions from the esophagus, sound pressure fields in a simple tissue model were numerically determined. Based on the simulation results for transducer arrays together with current transesophageal medical devices and the throat anatomy, we designed, fabricated, and tested a focused ultrasound applicator that can be inserted into the esophagus for non- invasive cardiac ablation. The ultimate goal in this project is to bring this applicator as close as possible to the heart to ef- fectively deliver ultrasound energy and create electrically isolating lesions in myocardial tissue, which replicate the cur- rently used Maze procedure. The transducer design is a two-dimensional sparse phased array with flat tapered elements operating at 1.6 MHz. This array uses 64 active elements spatially sampled from 195 rectangular elements. Its probe head housing is 19 mm in diameter and incorporates an acoustic window. A prototype applicator has been successfully tested in vitro using fresh porcine myocardial tissue. The results demonstrated a potential applicability of an ultrasound applicator to transesophageal cardiac surgery in AF treatment.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2010) studied Atrial fibrillation. Focused ultrasound applicator was evaluated. A prototype focused ultrasound applicator for non-invasive transesophageal cardiac ablation was successfully designed and tested in vitro using fresh porcine myocardial tissue.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: