Key result
ICE-guided TAVI with cusp-overlap view is associated with ~87% lower 30-day pacemaker implantation rates.
Why the study?
A high permanent pacemaker implantation risk remains a concern after self-expandable transcatheter aortic valve implantation despite improvements in implantation methodology.
Does transjugular intracardiac echocardiography (ICE) guidance during self-expandable transcatheter aortic valve implantation reduce 30-day permanent pacemaker implantation rates compared to methods without ICE?
Cohort (n=446)
Does transjugular intracardiac echocardiography (ICE) guidance during self-expandable transcatheter aortic valve implantation reduce 30-day permanent pacemaker implantation rates compared to methods without ICE?
Answers are grounded in this paper and cite their sources.
Transjugular ICE guidance during self-expandable TAVR using the cusp-overlap view significantly reduces the need for permanent pacemaker implantation at 30 days.
BACKGROUND: A high permanent pacemaker implantation (PPI) risk remains a concern of self-expandable transcatheter aortic valve implantation, despite the continued improvements in implantation methodology. We aimed to assess the impact of real-time direct visualization of the membranous septum using transjugular intracardiac echocardiography (ICE) during transcatheter aortic valve implantation on reducing the rates of conduction disturbances including the need for PPI. METHODS: Consecutive patients treated with Evolut R and Evolut PRO/PRO+ from February 2017 to September 2022 were included in this study. We compared outcomes between the conventional implantation method using the 3-cusps view (3 cusps without ICE group), the recent method using cusp-overlap view (cusp overlap without ICE group), and our novel method using ICE (cusp overlap with ICE group). RESULTS: Of the 446 patients eligible for analysis, 211 (47.3%) were categorized as the 3 cusps without ICE group, 129 (28.9%) were in the cusp overlap without ICE group, and 106 (23.8%) comprised the cusp overlap with ICE group. Compared with the 3 cusps without ICE group, the cusp overlap without ICE group had a smaller implantation depth (2.2 [interquartile range, 1.0–3.5] mm versus 4.3 [interquartile range, 3.3–5.4] mm; P <0.001) and lower 30-day PPI rates (7.0% versus 14.2%; P =0.035). Compared with the cusp overlap without ICE group, the cusp overlap with ICE group had lower 30-day PPI rates (0.9%; P =0.014), albeit with comparable implantation depths (1.9 [interquartile range, 0.9–2.9] mm; P =0.150). Multivariable analysis showed that our novel method using ICE with the cusp-overlap view was independently associated with a 30-day PPI rate reduction. There were no group differences in 30-day all-cause mortality (1.4% versus 1.6% versus 0%; P =0.608). CONCLUSIONS: Our novel implantation method using transjugular ICE, which enable real-time direct visualization of the membranous septum, achieved a predictably high position of prostheses, resulting in a substantial reduction of conduction disturbances requiring PPI after transcatheter aortic valve implantation.
No takes yet. Share an insight, caveat, or question.
Ishizu et al. (2023) conducted a cohort in Aortic stenosis requiring transcatheter aortic valve implantation (n=446). Cusp-overlap view with transjugular intracardiac echocardiography (ICE) vs. Cusp-overlap view without ICE (and conventional 3-cusps view without ICE) was evaluated on 30-day permanent pacemaker implantation (PPI) rate (p=0.014). TAVI using a cusp-overlap view with transjugular intracardiac echocardiography reduced 30-day permanent pacemaker implantation rates to 0.9% compared to 7.0% without ICE.
Synapse has enriched 10 related papers. Consider them for comparative context: