This paper presents aGₘ-C integrator-implanted DC servo loop (GMCI2-DSL) and a bulk-driven ripple reduction loop (BD-RRL) for bio-potential readout analog-front-end (AFE) amplifier. The proposed bio-potential readout AFE amplifier employs the GMCI2-DSL and BD-RRL to achieve low noise and significant total harmonic distortion (THD) with small ripple amplitude. A prototype has been taped out using a 0.18-μ mstandard CMOS technology, and the core circuit occupies 880μ m\,\,×630μ m. The mid-band gain is about 40 dB with a 1.3-V supply voltage, and the chip’s quiescent power is 10.8μ W. The measured results show that the input-referred noise density is 26 nV/Hz, and the input-referred integrated noise in the range from 0.5 Hz to 500 Hz is 0.93μ Vᵣₘₛ. The measured THD of a 5-mVₚₚinput sinusoidal signal at 5.1 Hz is −64.3 dB without any input offset. The amplitude of residue ripple is achieved as 197.8μ Varound chopping frequency (fch) by ripple suppression. High-fidelity and real-time electrocardiogram (ECG) signals are acquired.