Very accurate ultrasonic experiments have been performed to check the elastic isotropy of Al-Mn-Pd quasi-crystals. The velocities of ultrasonic waves propagating along a twofold or a fivefold axis have been found equal to (6521 ± 10) m · s-1 for longitudinal waves and (3292 ± 3) m · s-1 for shear waves. The accuracy of these measurements is one order of magnitude better than previous results. In addition, when the polarization of the shear waves propagating along a twofold axis is changed, the velocity is constant within an experimental uncertainty of 10-4. In this paper, we also report the first experimental evidence for anisotropic ultrasonic attenuation. Such an anisotropy is expected to occur for instance if phasons and phonons are coupled in the crystal.
No takes yet. Share an insight, caveat, or question.
Amazit et al. (1992) studied this question.