Key result
Post-op residual hypothermia linked to transient skeletal muscle O2 mismatch and elevated ~56% O2 extraction.
Why the study?
Thermoregulatory responses following coronary artery bypass graft surgery in haemodynamically stable patients were not fully characterized.
Observational (n=13)
Answers are grounded in this paper and cite their sources.
Residual hypothermia after cardiac surgery triggers thermoregulatory responses that cause a transient oxygen supply and uptake mismatch in skeletal muscles.
The thermoregulatory responses in 13 haemodynamically stable patients were evaluated over a 7-h period following coronary artery bypass graft surgery. Cutaneous vasoconstriction was defined by a forearm-to-fingertip skin temperature gradient (ΔTskin) ≥4°C and muscular hyperactivity was assessed by integrating the electromyographic signals (iEMG). Blood gases and lactate were measured in arterial, mixed venous and femoral venous blood. After arrival in ICU, we observed: (1) mild central hypothermia (Tc=34.8 ± 0.6°C) and elevated peripheral vascular resistance in all the patients; (2) ΔTskin ≥4°C in 11 of 13 patients that persisted until a median Tc of 37.1°C was achieved; (3) a transient increase in iEMG (+18%) was accompanied by an increase in total body O2 uptake (+28%); (4) elevated muscle O2 extraction rate (56 ± 18% after 3 h) and lactate release. These data suggest that residual hypothermia in sedated patients after cardiac surgery elicits appropriate thermoregulatory responses that are associated with transient O2 supply/uptake mismatch within skeletal muscles.
No takes yet. Share an insight, caveat, or question.
Licker et al. (1996) conducted an observational in Post-coronary artery bypass graft surgery (n=13). Coronary artery bypass graft surgery with residual hypothermia was evaluated on Thermoregulatory and metabolic responses (cutaneous vasoconstriction, muscular hyperactivity, blood gases, lactate). Residual hypothermia following cardiac surgery elicited thermoregulatory responses associated with transient O2 supply/uptake mismatch within skeletal muscles, including elevated O2 extraction.
Synapse has enriched 10 related papers. Consider them for comparative context: