Key result
Microvolt QRS alternans linked to ~3-fold higher ventricular arrhythmia risk in hypertrophic cardiomyopathy.
Why the study?
The relation between microvolt QRS alternans and ventricular arrhythmia risk has not been evaluated in hypertrophic cardiomyopathy.
Does the presence of microvolt QRS alternans predict late ventricular arrhythmias in patients with hypertrophic cardiomyopathy and prophylactic ICDs?
Cohort (n=130)
Does the presence of microvolt QRS alternans predict late ventricular arrhythmias in patients with hypertrophic cardiomyopathy and prophylactic ICDs?
Hazard Ratio: 2.9 (95% CI 1.2–7)
Absolute Event Rate: 5.8% vs 2%
p-value: p=0.019
Microvolt QRS alternans is a novel, rate-dependent risk marker that significantly predicts late ventricular arrhythmias in patients with hypertrophic cardiomyopathy.
QRSA may stratify VA risk in paced HCM; hypothesis-generating and should not change practice pending validation.
Background Unlike T‐wave alternans (TWA), the relation between QRS alternans (QRSA) and ventricular arrhythmia (VA) risk has not been evaluated in hypertrophic cardiomyopathy (HCM). We assessed microvolt QRSA/TWA in relation to HCM risk factors and late VA outcomes in HCM. Methods and Results Prospectively enrolled patients with HCM (n=130) with prophylactic implantable cardioverter‐defibrillators underwent digital 12‐lead ECG recordings during ventricular pacing (100–120 beats/min). QRSA/TWA was quantified using the spectral method. Patients were categorized as QRSA+ and/or TWA+ if sustained alternans was present in ≥2 precordial leads. The VA end point was appropriate implantable cardioverter‐defibrillator therapy over 5 years of follow‐up. QRSA+ and TWA+ occurred together in 28% of patients and alone in 7% and 7% of patients, respectively. QRSA magnitude increased with pacing rate (1.9±0.6 versus 6.2±2.0 µV; P =0.006). Left ventricular thickness was greater in QRSA+ than in QRSA− patients (22±7 versus 20±6 mm; P =0.035). Over 5 years follow‐up, 17% of patients had VA. The annual VA rate was greater in QRSA+ versus QRSA− patients (5.8% versus 2.0%; P =0.006), with the QRSA+/TWA− subgroup having the greatest rate (13.3% versus 2.6%; P <0.001). In those with <2 risk factors, QRSA− patients had a low annual VA rate compared QRSA+ patients (0.58% versus 7.1%; P =0.001). Separate Cox models revealed QRSA+ (hazard ratio [HR], 2.9 [95% CI, 1.2–7.0]; P =0.019) and QRSA+/TWA− (HR, 7.9 [95% CI, 2.9–21.7]; P <0.001) as the most significant VA predictors. TWA and HCM risk factors did not predict VA. Conclusions In HCM, microvolt QRSA is a novel, rate‐dependent phenomenon that can exist without TWA and is associated with greater left ventricular thickness. QRSA increases VA risk 3‐fold in all patients, whereas the absence of QRSA confers low VA risk in patients with <2 risk factors. Registration URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02560844.
No takes yet. Share an insight, caveat, or question.
A 2021 study conducted a cohort in Hypertrophic cardiomyopathy (n=130). Microvolt QRS alternans (QRSA) vs. Absence of QRS alternans (QRSA-) was evaluated on Appropriate implantable cardioverter-defibrillator therapy (ventricular arrhythmia) (HR 2.9, 95% CI 1.2-7.0, p=0.019). Microvolt QRS alternans was associated with a nearly 3-fold increased risk of late ventricular arrhythmias in patients with hypertrophic cardiomyopathy (HR 2.9; 95% CI 1.2-7.0; P=0.019).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: