Key result
Noninvasive Holter-derived SACT correlates strongly with the invasive Strauss method at r ~0.8.
Why the study?
The reliability of the noninvasive Holter method for calculating sinoatrial conduction time has not been confirmed by invasive electrophysiological studies.
Does the noninvasive Holter method provide reliable measurements of sinoatrial conduction time compared to the invasive Strauss method in patients with atrial premature beats?
Observational (n=61)
Does the noninvasive Holter method provide reliable measurements of sinoatrial conduction time compared to the invasive Strauss method in patients with atrial premature beats?
Effect estimate: r = 0.79
p-value: p=<0.001
The noninvasive Holter method provides a reliable calculation of sinoatrial conduction time that correlates well with invasive electrophysiological measurements.
Holter SACT correlates with invasive measures; leaves open whether it should replace electrophysiological testing in sinus node assessment.
BACKGROUND: The reliability of noninvasive Holter method for the calculation of sinoatrial conduction time (SACT) has not been confirmed by results of invasive electrophysiological studies of sinus nodal function. The aim of this study was to compare the values of SACT obtained by Holter method with values estimated by premature atrial stimulation method. METHODS: The study population consisted of 61 patients, in whom the 24-hour ambulatory ECG monitoring had shown the occurrence of atrial premature beats. All these subjects were undergoing electrophysiological study including programmed atrial and ventricular stimulation. The measurements of SACT were obtained using spontaneous atrial premature beats (Holter method) and high right atrial stimulation (Strauss method). RESULTS: There was a good correlation between measurements of SACT by Holter method and Strauss method (r = 0.79; P < 0.001). There was no significant difference between values of SACT estimated by two compared methods. However, in certain patients, there were appreciable differences and SACT measured using spontaneous premature beats was shorter in 34 and longer in 23 patients than that estimated by the Strauss method. The values of SACT calculated by Holter method and Strauss method were significantly (P < 0.001) higher in patients with sick sinus syndrome than in those without evidence of sinus node dysfunction. CONCLUSIONS: Good correlation between values of SACT obtained by two compared methods suggests that single measurement performed using Holter method may be adequate for reliable calculation of SACT.
No takes yet. Share an insight, caveat, or question.
Kramarz et al. (2014) conducted an observational in Atrial premature beats (n=61). Holter method (spontaneous atrial premature beats) vs. Strauss method (high right atrial stimulation) was evaluated on Sinoatrial conduction time (SACT) (r = 0.79, p=<0.001). Sinoatrial conduction time measured by the noninvasive Holter method correlated well with the invasive Strauss method (r = 0.79; P < 0.001).