A strategy for providing semi-direct cooling of SiC MOSFETs in an extremely power dense half-bridge module, while also serving as a source terminal interconnection is presented. This bussing structure with integrated cooling function provides topside (source) connection to 16 paralleled devices within a low inductance, 1.7 kV rated power module. Dielectric fluid coolant (HFE7500) in the microchannel (MC) manifold sustains the voltage discharge risk in the fluid but while not introduce risks associated with flooding the module with coolant. Meanwhile, it also achieves a low thermal resistance pathway between the device and to coolant as a single-phase coolant. Thermal characterization has been performed illustrating an effective thermal resistance of 0.54 cm2-°C/W across the 16 devices, with ample room for increased performance with optimized device topside attachment. This cooling approach inside of a bussing connector has the opportunity to increase module + cooler power density up to4×–5×of a traditional single-sided module, as well as reduce the thermal coupling effects inside a module.